Technical Specifications

Dimensions (W x H x D):
120 x 120 x 68 mm DualTech
120 x 120 x 73 mm Single US
120 x 120 x 68 mm US 360
120 x 120 x 73 mm Dual US
Power supply:
230 – 240 V, 50 Hz / 60 Hz
Capacity, switching output 1:
Relay, 230 V
(COM 1/COM 2)
2000 W max. resistive load (cos φ = 1)
1000 VA max. (cos φ = 0.5)
Electronic ballasts:
Max. ON current 800 A/200 μs
(COM 1/COM 1 AP/COM 2/DIM)
30 x (1 x 18 W), 25 x (2 x 18 W)
25 x (1 x 36 W), 15 x (2 x 36 W)
20 x (1 x 58 W), 10 x (2 x 58 W)
Pay attention to specific ON currents of electronic ballasts!
A relay or contactor must be provided on line side for
higher switching capacities
Capacity, switching output 2:
Presence
(COM 2 only)
230 W/230 V
1A max. (cos φ = 1) for HVAC (heating/ventilation/air-conditioning)
US 360/DualTech
Detection ranges:
(Detection
Tangential/presence (m): Ø 6 m max. (28 m
at 2.5 m / mounting
Ø 2 m min. (12 m
height 2.5 m)
Radial: Reach up to Ø 10 m
Light-level setting:
10 – 1000 lux, ∞ / daylight /
DIM 100 – 1000 lux control threshold
Switching output 1:
30 sec. – 30 min., pulse mode (approx. 2 sec.),
Time setting
IQ mode (automatic adjustment to the usage profile)
Switching output 2:
COM2 only, for HVAC
Time setting
0 sec. – 10 min. switch-ON delay
1 min. – 2 hrs. stay-ON time
Automatic room surveillance
DIM:
30 sec. – 30 min.,
Time setting
IQ mode (automatic adjustment to the usage profile)
Control output:
1 – 10 V / 50 electronic ballasts max., 100 mA max.
Mounting height:
2.5 m – 3.5 m
(mounted to ceiling)
Point of installation:
Indoors
Sensor technology:
DualTech
PIR (Passive Infrared), single pyro, 11 detection levels,
520 switching zones. Ultrasonic 40 kHz
US 360 / Single US / DualTech
Ultrasonic 40 kHz
IP rating:
IP 20
Protection class:
II
Temperature range:
- 25 °C - +55 °C
SingleUS/Dual US
)
2
)
2
3 x 10 m / 3 x 20 m (30 / 60 m²) max.
3 x 2.5 m / 3 x 5 m (7.5 / 15 m²) min.
- 22 -
Functions – Settings by DIP switch
COM 1 + COM 2
DIP 1
Normal mode / Test mode (NORM / TEST)
Test mode has priority over all
ambient light level, the presence
other settings on the presence
detector activates the light to
detector and serves the purpose
stay ON for approx. 8 sec. in
of checking for proper working
response to movement in the
order as well for testing the de-
room. (blue LED flashes when
tection zone. Irrespective of
movement is detected).
DIP 2
Semi-automatic mode (MAN) / fully automatic mode (AUTO)
Semi-automatic mode: (MAN)
The light now only switches
Light must be requested using
OFF automatically. Light is
the button and stays ON for the
switched ON manually.
time set at the potentiometer
Fully automatic mode: (AUTO)
The light automatically switches
matic switching function. Irre-
ON and OFF in relation to light
spective of the settings selected,
level when someone is present.
light stays ON for 4 hours after
Light can be switched ON and
manually pressing the button
OFF manually at any time. This
twice or switches OFF after man-
temporarily interrupts the auto-
ually pressing the button once.
DIP 3
Button/switch
Tells the sensor how to interpret
Operation either by button or
n
the incoming signal. Assigning
switch
external buttons/switches allows
Several buttons possible on
n
you to operate the detector as a
one control input
semi-automatic unit and over-
Only use illuminated pushbut-
n
ride it manually at any time.
ton with neutral conductor
connected
DIP 4
ON/ON-OFF button
In the ON-OFF setting, the light
pulse mode: no manual OFF).
can be switched ON and OFF
In the ON setting, light can no
manually at any time (except in
longer be switched OFF manual-
DIM
DIP 5
Constant light ON/OFF
Provides a constant level of
el of brightness. As daylight
brightness. Detector measures
changes, the switched-in artifi-
the prevailing level of daylight
cial lighting component is ad-
and activates sufficient artificial
justed accordingly. In addition to
the daylight component, artificial
light to achieve the required lev-
d
All user-selected potentiometer
settings apply in normal mode.
The presence detector can also
be set by means of the blue LED
without any load connected.
(pressing twice switches ON for
4 hours).
Pressing the button before the
4 hours elapse returns the pres-
ence detectors to the normal
operating mode.
Cable length between sensor
n
and switch < 50 m
ly. The stay-ON time starts from
the beginning again each time
the button is pressed.
light is also switched ON and OFF
in relation to whether or not per-
sons are present.
- 23 -