Herunterladen Inhalt Inhalt Diese Seite drucken

Set Address; User Mode; Function - EuroLite LED THA-250F COB Bedienungsanleitung

Theater spot
Vorschau ausblenden Andere Handbücher für LED THA-250F COB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Set Address

With this function, you can set the desired DMX-starting address via the Control Board.

User mode

With this function, you can set the DMX channel mode.

Function

Status
No DMX status
With this function, you can set different modes if there is no DMX-signal.
Close
Here you can close the shutter and set the device to center position if there is no DMX-signal.
Hold
Here the device remains in the last received DMX-program if there is no DMX-signal.
Dormancy - power standby mode
This function will be automatically activated after a predefined period of time of no DMX activity. In standby
mode the LEDs and motor will power down if no DMX signal is sent to the fixture for a period of e. g. 15
minutes (can be user defined). The fixture will automatically reset and return to normal operation once a
DMX signal is sent.
Fixture ID
Service PIN
The password for this function is „050".
RDM
With this function, you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated n the DMX-protocol without influencing the connections. The RDM-data is transmitted via
the standard XLR-poles 1 and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX
devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed
and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
In general, the device supports the following commands and functions via RDM:
Fan Set
With the function "Fan Set", you can adjust the ventilation fan mode.
Auto setting: To protect against overheating, the fan begins rotating at 45 ° C as measured by the thermal
sensor. At a temperature of about 70 ° C the device performance will reduce automatically, to protect the
LED.