Adjusting the DMX operating mode and start address
To control the device from a DMX lighting controller, adjust the DMX start address for its first DMX channel. The
start address is adjusted as a binary number via the DIP switches.
1
Set DIP switch 10 to the upper position (ON) to enable DMX mode.
⊳ Position of switch 10 for operation
2
The start address is will result by addition of the values of switches 1-9.
⊳ Example for address 20:
Note: Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX chain. If several devices are addressed similarly, they will
work synchronically.
Power supply:
Power consumption:
IP classification:
Power connection:
LED:
Flash rate:
DMX channels:
DMX input:
DMX output:
Beam angle (1/2 peak):
Housing color:
Width:
Height:
Depth:
Weight:
All information is subject to change without prior notice. © 04.01.2022
Jack plug connection:
Accessories
No. 51916211
No. 51916210
No. 58000650
No. 58000651
No. 58010250
No. 58010252
No. 70064504
with DMX controller
switches 3 and 5 in the upper position
TECHNICAL SPECIFICATIONS
230 V AC, 50 Hz
26 W
IP20
Fixed power supply cord with safety plug
1 x high-power 9 W 3in1 TCL RGB (homogenous color mix)
1 - 10 Hz
5
1 x 3.5 mm jack (stereo)
1 x 3.5 mm jack (stereo)
35°
Black
16.5 cm
17 cm
13.5 cm
0.9 kg
3 - Signal (+)
2 - Signal (-)
1 - Ground
EUROLITE DMX-Adapter IN Jack 3,5/XLR 1m
EUROLITE DMX-Adapter OUT Jack 3,5/XLR 1m
EUROLITE TH-50 Theatre Clamp silver
EUROLITE TH-50S Theatre Clamp black
SAVEKING Safety Bond 3x600 silver
SAVEKING Safety Bond 3x600 black
EUROLITE DMX LED Operator 4 Controller