Herunterladen Inhalt Inhalt Diese Seite drucken

Information - EuroLite LED THA-250F COB Bedienungsanleitung

Theater spot
Vorschau ausblenden Andere Handbücher für LED THA-250F COB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LCD. Set
Backlight
With this function you can shut off the display after 2 to 60 minutes.
Key lock
With this function, you can lock the buttons of the Control Board to e.g. prevent menu tampering. If this
function is activated, the buttons will be automatically locked in 15 seconds from the last command. In order
to deactivate or temporarily deactivate the key lock function, press the Mode button for 3 seconds to regain
access to the menu commands.
DispFlash
With this function, you can set the device that it will flash when there is no DMX signal received.
Temp. C/F
With this function, you can select the temperature designation.
Dimmer Curve
With this function, you can set various dimmer curves.
LINEAR: the increase in light intensity appears to be linear as DMX value is increased.
SQUARE LAW: light intensity control is finer at low levels and coarser at high levels
INVERSE SQUARE LAW: light intensity control is coarser at low levels and finer at high levels
S-CURVE: light intensity control is fine at low levels and high levels and coarser at medium levels.
Linear
Lamp Behavior
This function indicates the light impression, halogen or LED. In this case the display will show "L" for LED.
Load
With this function, you can reset the device to the default setting. Set Load to "ON".

Information

Time. Info
Current
With this function, you can display the temporary running time of the device from the last power on. The
display shows "XXXX", "X" stands for the number of hours. The counter is reset after turning the device off.
Total time
With this function, you can display the running time of the device. The display shows "XXXX", "X" stands for
the number of hours.
Last clear
This function allows the operator to record the operating hours of the device, according to his requirements.
You can use the counter to document the operating hours since the last service, for example, or to document
the operating hours from a rental. Individual operating hours can be reset at any time. The display shows
"XXXX"; "X" stands for the number of hours.
Timer PIN
Use this function to enter the password to clear the individual fixture running time. The password is „050".