Herunterladen Inhalt Inhalt Diese Seite drucken

Service Data - Balluff BOS 50K-PI-RD11-S4 Kurzanleitung

Rotlicht lichttaster energetisch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link

Service data

Diagnosis parameters
Index
(dec)
0x0024
Device Status
(36)
0x0025
Detailed
(37)
Device Status
0x0028
Process Data
(40)
Input
System commands
Index
(dec)
format
0x0002 (2)
System-
UINT8
Command
17
Subindex
Data format
Access
(dec)
0x00 (0)
UINT8
0x00 (0)
ArrayT of
OctetStringT3
0x00 (0)
UINT8
Data
Access
Value range
W
0x01 = ParamUploadStart
0x02 = ParamUploadEnd
0x03 = ParamDownloadStart
0x04 = ParamDownloadEnd
0x05 = ParamDownloadStore
0x06 = ParamBreak
0x40 = Teach Apply
0x43 = SP1 Two Value Teach TP1
0x44 = SP1 Two Value Teach TP2
0x45 = SP2 Two Value Teach TP1
0x46 = SP2 Two Value Teach TP2
0x47 = SP1 Dynamic Teach Start
0x48 = SP1 Dynamic Teach Stop
0x49 = SP2 Dynamic Teach Start
0x4A = SP2 Dynamic Teach Stop
0x4B = SP1 Fine Adjustment Near
0x4C = SP1 Fine Adjustment Far
0x4D = SP2 Fine Adjustment Near
0x4E = SP2 Fine Adjustment Far
0x4F = Teach Cancel
0x80 = Device reset
0x82 = Restore factory settings
0xA0 = Restore BDC
Value range
R
0x00 = Device OK
0x02 = Out of Specification
0x03 = Functional Check
R
Over temperature
Low voltage
R
Block
Start Block Parameterization Device
Parame-
Stop Block Parameterization Device
terization
Start Block Parameterization Master
Stop Block Parameterization Master
Stop Block Parameterization Master
Teach
Channel
Reduce SP1 switching distance with every
Increase SP1 switching distance with every
Reduce SP2 switching distance with every
Increase SP2 switching distance with every
Reset
Remark
Existent Low voltage or Over
temperature
during Teach-In
Implemented as a dynamic list
See also Process data
Remark
and Upload Request
Abort Block Parameterization
Store and accept switching points
Teach TP1 of SP1
Teach TP2 of SP1
Teach TP1 of SP2
Teach TP2 of SP2
Start Dynamic Teach for SP1
Stop Dynamic Teach for SP1
Start Dynamic Teach for SP2
Stop Dynamic Teach for SP2
command 0x4B
command 0x4C
command 0x4D
command 0x4E
Abort Teach-In via Teach Channel
Device reset
Reset sensor to factory settings
Reset BDC addressed with Teach-In
Channel to factory settings
Master
Master
Device
Device
Device

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis