Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link
Service data
Profile specific parameters
Index
Subindex
(dec)
(dec)
0x003A
Teach-In
0x00 (0)
(58)
Channel
0x003B
Teach-In
0x00 (0)
(59)
Status
0x003C
Set Point
0x01 (1)
(60)
Value (BDC1)
0x02 (2)
0x003D
Switch Point
0x01 (1)
(61)
Configuration
(BDC1)
0x02 (2)
0x03 (3)
0x003E
Set Point
0x01 (1)
(62)
Value (BDC2)
0x02 (2)
0x003F
Switch Point
0x01 (1)
(63)
Configuration
(BDC2)
0x02 (2)
0x03 (3)
0x4000
Set Point
0x01 (1)
(16384)
Value (BDC3)
0x02 (2)
0x4001
Switch Point
0x01 (1)
(16385)
Configuration
(BDC3)
0x02 (2)
0x03 (3)
0x4002
Set Point
0x01 (1)
(16386)
Value (BDC4)
0x02 (2)
0x4003
Switch Point
0x01 (1)
(16387)
Configuration
(BDC4)
0x02 (2)
0x03 (3)
* Std Hysteresis = 0x78 (120)
*Plausibility checks
In Window Mode and Two Point Mode SP1 has to be the near and SP2 the far switching point of a BDC.
www.balluff.com
Data format Access
UINT8
UINT8
Setpoint SP1
UINT16
Setpoint SP2
UINT16
Switchpoint
UINT8
logic
Switchpoint
UINT8
mode
Switchpoint
UINT16
hysteresis
Setpoint SP1
UINT16
Setpoint SP2
UINT16
Switchpoint
UINT8
logic
Switchpoint
UINT8
mode
Switchpoint
UINT16
hysteresis
Setpoint SP1
UINT16
Setpoint SP2
UINT16
Switchpoint
UINT8
logic
Switchpoint
UINT8
mode
Switchpoint
UINT16
hysteresis
Setpoint SP1
UINT16
Setpoint SP2
UINT16
Switchpoint
UINT8
logic
Switchpoint
UINT8
mode
Switchpoint
UINT16
hysteresis
**Std Threshold = 0x0104 (500)
Value range
R / W
0x00 (0)
0x01...0x04 (1...4)
0xFF (255)
R
See Smart Sensor Profile
R / W
Std Threshold**
R / W
Std Threshold**
R / W
0x00 = N.O.
0x01 = N.C.
R / W
0x01 = Single point Mode
R / W
Std Hysteresis*
R / W
Std Threshold**
R / W
Std Threshold**
R / W
See Index 0x3D
R / W
0x00 = Deactivated
0x01 = Single Point Mode
0x02 = Window Mode
0x03 = Two Point Mode
R / W
Std Hysteresis*
R / W
Std Threshold**
R / W
Std Threshold**
R / W
See Index 0x3D
R / W
See Index 0x3F
R / W
Std Hysteresis*
R / W
Std Threshold**
R / W
Std Threshold**
R / W
See Index 0x3D
R / W
See Index 0x3F
R / W
Std Hysteresis*
Remark
BDC1 (Standard)
BDC1...BDC4
All BDC
All BDC
Functionally not supported.
Sensor does plausibility
checks for SP1 and SP2
Functionally not sup-
ported
Functionally not supported.
Sensor does plausibility
checks for SP1 and SP2
Functionally not sup-
ported
Functionally not supported.
Sensor does plausibility
checks for SP1 and SP2
Functionally not sup-
ported
Functionally not supported.
Sensor does plausibility
checks for SP1 and SP2
Functionally not sup-
ported