Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS 50K-PI-RD11-S4 Kurzanleitung Seite 20

Rotlicht lichttaster energetisch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link
Switchpoint mode
BDC1 can be solely operated in Single Point Mode
and is shared between IO-Link and SIO mode.
In IO-Link mode BDC2 to BDC4 can be operated in
Single Point, Window, or Two Point Mode.
Switchpoint mode
Single
Window
Point Mode
Mode
N.O.
N.C.
N.O.
BDC1
SIO
SIO
IO
IO
BDC2
IO
IO
IO
BDC3
IO
IO
IO
BDC4
IO
IO
IO
IO = IO-Link mode
SIO = SIO mode
Teach-In
Butten- and Channel-Function
The Teach Button can be used in SIO mode and in IO-Link
mode.
Using Teach Button only the sensitivity of SP1 of BDC1
can be set.
If Teach Button is locked in IO-Link mode it will stay locked
after a fallback to SIO mode.
In IO-Link mode the sensitivity of all BDC can be set with
Teach Channel.
www.balluff.com
Two Point
Deac-
Mode
tivated
Mode
N.C.
N.O.
N.C.
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
IO
Single Point Mode
BDCx
N.O.
-
s
SP1
SP1 Hyst
Two Point Mode
BDCx
N.O.
s
SP1
SP2
Window Mode
BDCx
N.O.
s
SP1
SP1
SP2
SP2
+
-
Hyst
Hyst
Deactivated Mode
N.O.: BDCx = 0
N.C.:
BDCx = 0
Button- und
BDC1
Channel-
SP1
SP2
SP1
Functions
Teach Button
SIO
IO
Teach Channel
IO
IO
IO
IO = IO-Link mode
SIO = SIO mode
BDCx
N.C.
-
s
SP1
SP1
Hyst
BDCx
N.C.
s
SP2
SP1
BDCx
N.C.
s
SP1
SP2
SP2
SP1
-
+
Hyst
Hyst
BDC2
BDC3
BDC4
SP2
SP1
SP2
SP1
SP2
IO
IO
IO
IO
IO