Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS 50K-PI-RD11-S4 Kurzanleitung Seite 13

Rotlicht lichttaster energetisch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link
Safety Notes
These photoelectric sensors may not be used in
applications where personal safety depends on
proper function of the devices (not safety
designed per EU machine guideline). Read
these operating instructions carefully before
putting the device into service.
Exempt Group according to EN 62471:2008.
DO NOT STARE INTO THE LIGHT BEAM!
Danger of glare and irritation!
The sensor must be installed so that no direct
looking into the light source is possible even
during operation.
The CE Marking confirms that our products
conform to the EC Directives 2004/108/EEC
(EMC) and the EMC Law.
In our EMC Laboratory, which is accredited by
the DATech for Testing of Electromagnetic
Compatibility, proof has been documented that
these Balluff products meet the EMC require-
ments of the harmonized standard EN 60947-5-2.
Display- and Operating Elements
green LED: Power on indicator
yellow LED: Light reception indicator
In IO-Link mode: light reception indicator for BDC1
Teach button
Fig. 1: Display and operating Elements
Green LED Power on indicator
LED on: The sensor is operating.
LED off: Sensor not ready
LED flashes: Short circuit on the output.
Yellow LED light reception indicator
LED on: Light at the receiver
LED flashes at function reserve < 1.5. Unreliable range
Teach button
Used for setting of the switching point and for changing
the light-on/dark-on output function..
13
Order code
Diffuse reflective energetic with IO-Link
BOS01JJ
BOS 50K-PI-RD11-S4
New sensor technology enables previously unattainable switching distances or
detection of weakly reflective objects
Function reserve indicator for high operating reliability
Rugged housing
Convenient setting via IO-Link and teach-in
Highly visible light spot for ease of alignment
Comprehensive parameter setting options
PNP
Installation
Attention!
Do not stare into the light beam.
Fig. 2: Dimensions
Wiring diagramms
BOS 50K-PI...
PNP
1
2
4
3
1
3
M12
4
Fig. 3: Connection diagram, pinouts
Sensor replacement
Sensor replacement may require a re-parameterization of
the switching points.
NO/NC (selectable)
BN
+18...30 V DC
BK
Out / IO-Link
BU
- 0 V

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis