Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link
Technical Data
Optical
Range
Light type
Wave lenght l
LED-Gruppe acc. to IEC 62471
Light spot size at sr max.
Electrical
Supply voltage U
B
Rated operating voltage U
No-load current I
O
Effective operating current I
Permissible capacitance
Voltage drop U
at I
d
e
Hysteresis
Output depending on version
Short circuit protected
Reverse polarity protected
Output function dark-on/ light-on
Sensitivity setting
Protection class
Time (SIO-Mode)
Turn-on delay
Turn-off delay
Switching frequency f
IO-Link Data
Transmission rate
Minimum cycle time
Mechanical
Connection type dep. on version
Housing material
Active surface material
Housing dimensions
Weight
Displays
Light reception indicator
Function reserve < 1.5
Power on
Short circuit on the output
Ambient
Ambient temperature T
a
Enclosure rating per IEC 60529
Ambient light rejection
Reference material
15
1...3500 mm
red light
630 nm
Exempt Group
< 80 x 80 mm
10...30 V DC
24 V
e
< 50 mA
100 mA
e
< 0.3 µF
< 0,7 V
< 15%
PNP
yes
yes
switchable (Pin 4)
Teach-In: using
button or via IO-Link
II
< 2.5 ms
< 2.5 ms
200 Hz
38.4 kbit/s (COM2)
4.8 ms
M12-connector, 4-pin
270° rotatable, with
detents
ABS/PC
Glas
28.5 x 62 x 80.5 mm
95 g
yellow LED
yellow LED (flashing)
green LED
green LED (flashing)
–5... +55°C
IP 67
10 kLux
gray card,
90%/18% Remission,
200 x 200 mm
2
Process data
Output data
Sensor transmits 1 octet of process data to Master.
(M-Sequence Type: TYPE_2_1)
Byte 0
7
6
5
4
BDC1...4 Switching point information BDC1....4:
"1"
active
"0"
inactive
Stability
"1"
At least 1 BDC in unreliable range (Unre-
liable range: Function reserve ≤ 1.5)
"0"
Switching point information in reliable range
Teach-In
"1"
Teach-In active
"0"
Teach-In inactive
Input data
Sensor does not receive process data from Master.
Smart Sensor Profile
Device identification
Smart
Sensor
Teach Channel
Binary Data Channel
Diagnosis
Fig. 6: Smart Sensor functions
3
2
1
0
Two Value Teach
Dynamic Teach
Single Point Mode
Window Mode
Two Point Mode
Deactivated Mode

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis