Photoelectric Sensors
Red light diffuse reflective energetic BOS 50K-...-PI11-S4 with IO-Link
With Teach Channel: Dynamic Teach. Dynamic Teach-In of 1 setpoint
Principle
Dynamic teach-in allows you to set the switching point
without interrupting the process.
Typical application: Sensitivity setup to a process running
perpendicular to the light beam of the sensor
During the teach procedure, which begins with the Start
command and ends with the Stop command, the sensor
carries out measurements and determines the minimum
and maximum of the obtained values. The Teach Apply
command determines the switching point SPy.
Dynamic Teach
max
SPy
min
1
0
x = 1, 2, 3, 4
y = 1, 2
Teach-In Status
Teach Flags
SP2
SP1
TP2
TP1
TP2
TP1
Example for:
"0" = TP1 of SP2 not set
or not successfully set
"1" = TP1 of SP2 success-
fully set
Instructions
Dynamic Teach is explained for SP1 as an example.
The same sequence can be applied for SP2 with the
corresponding instruction set.
Precondition:
Sensor is installed, aligned to the running process and
operated in IO-Link mode.
Procedure:
1. Set Teach-In Channel.
Access Index
Value
W
0x003A
0x00
0x01...0x04
0xFF
www.balluff.com
(Conveyor).
System commands
SPy Dynamic Teach Start
(
Teach Start
)
SPy Dynamic Teach Stop
(
Teach Stop
)
Teach Apply
(
Set SPy
)
s
Teach State
0 = IDLE
1 = SP1 SUCCESS
2 = SP2 SUCCESS
3 = SP12 SUCCESS
4 = WAIT FOR COMMAND
5 = BUSY
6 = reserved
7 = ERROR
Remark
Standard BDC (BDC1)
BDC1...BDC4
All BDC
2. Start Dynamic Teach:
Send System command 0x47 to sensor.
Access Index
Value
W
0x0002
0x47
3. Wait for a minimum of one process cycle is completed.
(>10 min: Dynamic Teach is aborted automatically.
Sensor keeps operating with last valid Setpoint set-
tings).
4. Stop Dynamic Teach:
Send System command 0x48 to sensor.
Access Index
Value
W
0x0002
0x48
5. Verify successful sensitivity setup:
Read and verify parameter Teach-In Status with Index
0x003B.
Access Index
Value
R
0x003B
0x34
Dynamic sensitivity setup of SP1
Teach-In State = WAIT FOR
0x07
Teach-In State = ERROR
6. Store and accept Setpoint SP1:
Send System command 0x40 to sensor.
Access Index
Value
W
0x0002
0x40
7. Verify correct acceptance of SP1:
Read and verify parameter Teach-In Status with Index
0x003B.
Access Index
Value
R
0x003B
0x01
SP1 accepted successfully.
Teach-In State = SP1 SUCCESS
0x07
Teach-In State = ERROR
Remark
SP1 Dynamic Teach Start
Remark
SP1 Dynamic Teach Stop
Meaning
Result
Proceed with 6
successful
COMMAND
Back to 2
Remark
Teach Apply
Meaning
Result
Teach-In
successful
(0x01)
Back to 2