Check the required power supply. The operating voltage is announced
on the marking plate of the b-intense MED (see page 80).
To avoid the risk of electric shock, this device must only be connected to a
mains supply with a protective earth conductor.
The accessability of the mains plug must always be ensured for disconnec-
ting from the mains supply in an emergency.
Only original b-intense
component parts are safe for use. The use of not cer-
®
tified components can lead to damages or injuries. Waranties and guarantees
expire with the use of not certified components.
1. The used socket should be secured with a fault-current circuit
breaker (FI) with a trip current of max 30mA and a circuit breaker (safety
device) of max 16A.
2. The electrical installation must be checked annually by a licensed electri-
cal company.
3. The IR cabin must not be operated on a multiple socket (fire hazard).
4. The used socket should be easily accessible after installation.
5. The IR cabin must only be operated on an earthed shockproof socket,
which was installed and checked by a lincensed electrical company.
6. Only the original power cable with the length of 3 m must be used for
connection to the power supply.
7. The power cable is not allowed to be extended.
36 36