Initialisation/reset

Following assembly, or when the desk has been disconnected from the power supply for an extended period
of time, or if a fault has occurred on the desk, or if the connection between the drives and the control unit was
interrupted, the desk's control unit has to be initialised.
If the control element unit expects a new initialisation, only lowering of the desk at reduced speed is possible.
On the control elements with display, this is also indicated with the notification "RST", which disappears once
initialisation has been completed successfully.
To start initialisation, move the desk into its bottommost position. To do so, press and hold the "down" button
on the control element until all the drives have reached the bottommost position. Then, press the "down"
button again and hold it for at least 10 seconds. In the case of control elements with display, RST is shown on
the display. Now press the "down" button again until the desk moves down slightly and then up again. Only
release the button once the desk has stopped moving. If the button is released too soon, this causes a desk
malfunction. If the button was released early by accident, you must repeat the process.
The top limit position is pre-set in the control unit. For this reason, only control units that were provided for
the respective desk frame may be used.
Danger: During all reset processes, collision protection is not active. Note that there is a
potential crushing hazard in this situation.