Operating instructions
7�3
Installation of the CLICKMATE
11
Î
Unscrew the existing screw filling connection from the filling bar.
Î
Premount the adaptor (Pos. 14).
Î
Put the union nut (Pos. 12) onto the adaptor (Pos. 14).
Î
Insert the O-ring (Pos. 15) into the appropriate groove of the adaptor (Pos. 14).
Î
Screw the adaptor (Pos. 14) completely into the filling bar.
Tightening torque 20 Nm ± 2 Nm
Î
Lightly grease the O-ring (Pos. 13) with WEH
insert it into the plan recess of the adaptor (Pos. 14).
Î
Screw the union nut (Pos. 12) onto the operating media inlet "B1" of the adapter.
Note: The bail of the adapter must be aligned horizontally.
Î
Tighten the union nut (Pos. 12). While tightening, hold the wrench size A/F(1) of the
adapter.
For the tightening torque, please refer to the table below.
Connection
Union nut
M16x1.5 male thread
Î
Please note the connection size marked on your product.
- Other connection sizes are available on request.
Page 18
MD-10081-L51-R1.1.0-03
TW154 FL with the adaptor W30225
®
15
14
B1
12
13
®
Pos�
Description
11
CLICKMATE
12
Union nut
13
O-ring
14
Adaptor
15
O-ring
Definition of ports
B1
Media inlet
Lubricant part no. E99-10 and then
Torque
20 Nm ± 2 Nm
20 Nm ± 2 Nm
TW154
®