burns as environmentally friendly as possible. The height of the chimney must typically be a mini-
mum of 3.5 m from the top of the stove to the top of the chimney.
The chimney must have a minimum internal diameter of Ø150mm.
The chimney must be equipped with an easily accessible cleaning hatch. All joints and connec-
tions must be tight and the chimney must be able to provide a draught of at least 1.2 mm water
gauge (12Pa).
It is possible to connect the wood-burning stove to chimneys that are also used for other purpo-
ses. However, the concrete conditions must be assessed by the fitter and/or chimney sweeper.
If the stove is to be mounted with back/rear exit the following is done (TT23RG/
TT23RGS): The round, welded or screwed cover plate at the back of the stove is removed. Then
the cut-out piece on the base-plate is removed (the thin division plate). Be careful not to drop the
piece between the back plate and the stove! This is best done with a screwdriver / chisel or pliers.
Finally the screwed smoke cover is removed and then the exhaust branch can be mounted.
Remember to fix the smoke cover at the top of the stove before use.
If the stove is to be mounted with back/rear exit the following is done (TT23RGW):
When the wall bushing and wall bracket are mounted, insert the supplied flue pipe - remember
the gasket between the pipe and the wall bushing. The 2 pins on the outside of the pipe will thus
abut the wall bushing and the pipe can thus not slide into the wall bushing. Remember to shorten
or lengthen the tube so that it has the correct length.
The stove can then be mounted.
Demands for the floor:
The foundation must be able to bear the stove and possibly the chimney's weight (Not TT23RGW).

INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS

Installation in a smoke control area requires the additional assembling / installation of the "Dam-
per control unit" which must be installed by the installer. See drawing and picture on page 37.
LIGHTING INSTRUCTION

The first time

The first time the stove is lit is must be done gently as all the materials need to get use to the
heat. The Senotherm varnish that the stove is painted with will harden the first couple of times
the stove is heated, and it may cause some odour nuisances. So make sure that you have proper
ventilation. Do not touch the painted surface, when the stove is hot. The painting has to harden
up first.
Use of the stove
Below is the procedure used for testing/approval of the stove. It is this procedure that will lead to
the best combustion for the given chimney. Firewood amount and damper setting can be adjusted
to the individual need for heating and the draught in the chimney.
On your new TT23 the work with controlling the air input has been simplified so there is only one
damper (below the door).
Between the left position and the middle position you have the normal working area where you
control the air input.
No air = left position and
Maximum air = middle position.
As help for lighting the damper can be pushed completely to the right. This start help adds some
air from below an ensures faster lighting. After a few minutes the damper is returned to the nor-
mal working position (between the left and middle position).
Lighting and continuous firing at CE/EN-testing
1. The damper/start-up device can be opened (the damper is pushed to the right) for a few mi-
nutes at lighting. Put about 12-15 kindling sticks (dia. 2-5 cm) in the bottom of the stove, laid in
a criss-cross pattern as a log house. Put 2 firelighters in the middle and light them.
2. Leave the door ajar so there is an opening of about 1 cm (TT23 see page 68). Leave the stove
like that for about 5 minutes before you close the door completely. Stay by the stove as long as
the door is ajar. The damper must now be set/placed in the working area (middle position).
3. When the fire has burned to embers (there are no more flames) open the door gently so the
ash is not whirled out through the door. Gently spread out the embers with a poker so they are
even.