Herunterladen Diese Seite drucken

Kaisai KCD-24 Bedienungsanleitung Seite 32

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ECO/GEAR function
Press X-ECO button to enter the energy efficient mode in a sequence of
following:
ECO
GEAR(75%)
Note:This function is only available under COOL mode.
ECO operation:
Under cooling mode, press this button, the remote controller will adjust the temperature
automatically to 24 C/75 F, fan speed of Auto to save energy (only when the set temperature
O
O
is less than 24 C/75 F). If the set temperature is above 24 C/75 F, press the ECO button,
O
O
the fan speed will change to Auto, the set temperature will remain unchanged.
NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set temperature to less
than 24 C/75 F will stop ECO operation.
O
O
Under ECO operation, the set tmeperature should be 24 C/75 F or above, it may result in
insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
GEAR operation:
Press the ECO/GEAR button to enter the GEAR operation as following:
75%(up to 75% electrial energy consumption)
50%(up to 50% electrial energy consumption)
Previous setting mode.
Under GEAR operation, the display on the remote controller will alternage between
electical energy consumption and set temperature.
GEAR(50%)
Previous setting mode
O
O
O
O
62
Silence function
2s
ECO......
FP function
Press this button 2 times during one second under HEAT Mode and setting temperature of
16 C/60 F or 20 C/68 F(for model RG10A10(B2)/BGEF).
O
O
O
2
Note: This function is for heat pump air conditioner only.
Press this button 2 times under HEAT Mode and setting temperature of 16 C/60 F to activate
the FP function. Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel
this function.
LOCK function
5s
+
Clean
Keep pressing Fan button for more than 2 seconds to activate/disable Silence
function(some units).
Due to low frequency operation of compressor, it may result in insufficient cooling
and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while
operating will cancel silence function.
O
The unit will operate at high fan speed (while
compressor on) with temperature automatically
set to 8 C/46 F.
5s
Press together Clean button and Boost button at the
Boost
same time more than 5 seconds to activate Lock function.
All buttons will not response except pressing these two
buttons for two seconds again to disable locking.
63

Werbung

Fehlerbehebung

loading

Diese Anleitung auch für:

Kcd-36Kcd-48Kcd-55