5.2.2 Using the main menu

To open the main menu, press the
ECM button and button no. 3 on the
left control panel.
Main menu A – F:
A = boiler temperature
b. = autosteamer temperature
c =
reminder function for group cleaning
d =
regulation of the preinfusion
E =
regulation pre-infusion volume
F =
regulation pre-infusion time
The menu items E and F are only relevant if any type of pre-infusion is selected in the menu
item d. See chapter 5.2.5 for the regulation of the pre-infusion.
Navigating within the menu:
To confirm a selected menu item press the ECM button.
When opening the main menu, the display indicates the last menu item that had been
selected before exiting.

5.2.3 Programming the boiler temperature - A

Open the menu item A and confirm by pressing the ECM button. The current set temperature is indicated on
the display. E. g.: The display alternately indicates the numbers 01 and 17 for 117°C. Pressing button no.2
increases the temperature while pressing the button no. 1 decreases it. To confirm the selected
temperature, press the ECM button. Now you are back in the main menu. After a short while you will
automatically exit the menu.
Setting range: 80° - 125° C
Translation of the original German user manual
button no. 2 – up
button no. 1 – down
(e. g. in the main menu from A to F)
(e. g. in the main menu from F to A)