Herunterladen Inhalt Inhalt Diese Seite drucken

Pid-Menu; Programming The Temperature Via The Pid-Display - ECM Manufacture Puristika Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.3.1 PID-menu

PID
menu sequence
93
Temperature value
t1
Temperature setting
CLn
Group cleaning mode
ECo
ECO mode
o
Temperature mode
When the desired value has been reached, wait a short time and you will exit the menu automatically

6.3.2 Programming the temperature via the PID-display

During normal use, the temperature is indicated on the display. The coffee temperature control is pre-
programmed to 93°C.
1. Switch the machine on in order to activate the boiler. The temperature
of the boiler is of no importance for programming. The heater is inactive
during programming.
2. Press + and – at the same time until 't1' appears on the display,
3. Press + in order to progress to the submenu of 't1' and to change the
temperature value. The nominal temperature value is displayed.
Translation of the German original user manual
Selec
Mode
tion
t1
CLn
ECo
o
Action
Change of setting
Temperature value is increased
Temperature value is reduced
Programming in steps of 10 between 0 and
200.
Programming in steps of 30. Adjustable
time between 0 and 600 min.
Selection between C for Celsius and F for
Fahrenheit