Herunterladen Inhalt Inhalt Diese Seite drucken

Fault Tracing - FAS Euroline Bedienungsanleitung

Beutelherstellungsmaschinen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fault tracing

CF-unit
Fault
No seal or poor
Circuit breaker released.
seal.
Web tension in machine.
Carbon brushes worn or
make poor contact
against the copper lines.
Seal wire broken.
Poor perfora-
Perforating knives worn
tion.
or incorrectly set.
Incorrect bag
Incorrect bag length set.
length.
The shaft encoder on the
variator gives the wrong
number of pulses.
Shaft encoder damaged.
Machine runs
Dancing roller potenti-
unevenly and
ometer or thyristor con-
jerky.
trol faulty.
Servo motor not
See separate instruction.
running.
June 2014
Fault tracing
Probable cause
BW / U 900
Remedy measure
Reset the circuit breaker.
Adjust the web tension in Web Tension menu.
The variator belt slips. Clean the belt and var-
iator with suitable degreasing agent.
Possibly spray the belt with special spray.
Tighten the variator belt.
Check, and possibly change, the number of
weights on the SPINNER dancing roller accu-
mulator.
Low pressure on the nip roller, it should be 3
bar.
Pressure between cooling bars too low. Check
by pulling a bag through the bars. See
"Adjustment of cooling bar pressure" on page
40.
Polish the carbon and copper lines with emery
cloth. Possibly exchange the carbon for new
item.
Exchange the seal wire for new item.
NOTE that when exchanging the seal wire,
Teflon and silicon, must be replaced on all
seal wires at the same time.
Sharpen the knives and reset them. They must
not hit to hard against the anvil roller.
Check the setting.
Check to make sure that the shaft encoder is
fitted securely on the variator.
Exchange the shaft encoder for new item.
Check the function.
Follow below instructions, fill in the paper
form and contact FAS Converting Machinery
AB Att. Service department.
48

Werbung

Inhaltsverzeichnis
loading