Adjustment of sealing bar
pressure
1 Loosen, but do not remove, the five bolts.
2 Use the two adjusting screws to adjust the
pressure between the sealing bars, see Fig.
30. Make sure that both screws are adjusted
equally in order to keep the sealing bars
parallel with equal sealing pressure during
the sealing process.
3 For factory settings, see Fig. 31.
4 Retighten the five bolts.
5 Repeat on other side.
Note
Adjust only on the two sideplates
equipped with adjustment screws,
(outfeed side of machine).
Adjustment of cooling bar
pressure
1 Loosen, but do not remove, the three bolts.
2 Use a pinch bar to adjust the pressure
between the upper part of cooling bars, see
Fig. 32.
3 For factory settings, see Fig. 31.
4 Retighten one of the bolts.
5 Loosen, but do not remove, the three bolts.
6 Use a pinch bar to adjust the pressure
between the lower part of cooling bars, see
Fig. 32. Adjusted equally as on upper part
in order to keep the cooling bars parallel
with equal pressure.
7 Retighten the bolts.
8 Repeat on the other side of the machine.
Note
Adjust only on the two sideplates
located on the outfeed side of
machine.
June 2014
CF-unit
1
Fig. 30
Sealing bar
Pressure
Cooling bar
Pressure
Fig. 31
Fig. 32
BW / U 900
3
B XXXX E27
B XXXX E19
30 mm
22 mm
22 mm
22 mm
3
5
2
1
40

Werbung