Herunterladen Inhalt Inhalt Diese Seite drucken

Alarm List - FAS Euroline Bedienungsanleitung

Beutelherstellungsmaschinen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Alarm list

Alarm
Dancer down stop
Sealalarm stop
Seal alarm 2
Low current seal 1 The current has decreased below the preset alarm level which is set in
Safety bypassed
No sealing
Over current trip
Ext stop order
Photo cell
Perf heat
June 2014
Alarm list
The machine has stopped because dancing roller is at its lowest posi-
tion, (provided Dancer down stop is set to ON in menu F4).
The machine has stopped due to a seal alarm, (provided Sealalarm stop
is set to ON in Menu F4) Seal alarm 1 There is a short circuit or break
in the circuit for seal 1. To discontinue press the blue reset button on
the Omron Power Controller A6. The machine will stop if Sealalarm
stop is set to ON in Menu F4.
There is a short circuit or break in the circuit for seal 2. To discontinue
press the blue reset button on the Omron Power Controller A7. The
machine will stop if Sealalarm stop is set to ON in Menu F4.
menu F3. The machine will stop if Sealalarm stop is set to ON in Menu
F4. Low current seal 2 The current has decreased below the preset
alarm level which is set in menu F3. The machine will stop if Sealalarm
stop is set to ON in Menu F4. Nip open The nip is open during opera-
tion. Close the nip using the nip switch on the control panel.
The safety bypass keyswitch is set to "hand" during operation.
The seal has not been activated within 30 seconds after production
starts or, if sealing is deactivated, during production.
The current consumption has exceeded the limit. Check the frequency
controller, the contactors F1 for main motor and F2 for servo drive.
Turn off the main power before resetting the fuse F2 Dancer down The
dancing roller is at its lowest position, (provided Dancer down stop is
set to ON in menu F4).
The machine has stopped due to an external stop order from an inter-
locked equipment.
The photo cell misses a number of marks which exceeds the number set
in NBR OF MARKS in display F2. On restart the photocell must detect
at least one print before normal operation.
The temperature in the perforator has exceeded the preset limit value.
Table 3:
BW / U 900
Cause
47

Werbung

Inhaltsverzeichnis
loading