10.2 Maintenance work on the pressure vessel/
condensed water (fig. 1)
m Important!
To ensure a long service life of the pressure ves-
sel (5), drain off the condensed water by opening
the drain valve (7) each time after using.
Release the vessel pressure first (see 10.8). Open
the drain screw by turning counter-clockwise (looking
at the screw from the bottom of the compressor) so
that all the condensed water can run out of the pres-
sure vessel. Then close the drain screw again (turn
it clockwise). Check the pressure vessel for signs
of rust and damage each time before using. Do not
use the compressor with a damaged or rusty pres-
sure vessel. If you discover any damage, then please
contact the customer service workshop.
10.3 Safety valve (fig. 2)
The safety valve (15) has been set for the highest per-
mitted pressure of the pressure vessel. It is not permit-
ted to adjust the safety valve or remove the connec-
tion lock (15.2) between the exhaust nut (15.1) and its
cap (15.3).
Actuate the safety valve every 30 operating hours but
at least 3 times a year, to ensure that it works when
required. Turn the perforated exhaust nut (15.1) coun-
terclockwise to open it and use your hands to pull the
valve rod outwards over the perforated exhaust nut
(15.1) to open the safety valve outlet. Now, the valve
audibly releases air. Then, tighten the exhaust nut
clockwise again.
10.4 Checking the oil level at regular intervals
(fig. 9)
Place the compressor on a level and straight surface.
The oil level must be between the MAX and MIN
marks on the oil level window (17).
Oil change: we recommend SAE 15W 40 or equiva-
lent.
The original oil filling must be changed after 10 hours
in operation; thereafter the oil must be drained and
replaced with new oil after every 50 hours in opera-
tion.
10.5 Changing the oil (Fig. 9)
Switch off the engine and pull the mains plug out of
the socket. After releasing any air pressure you can
unscrew the oil drain plug (18) from the compressor
pump. To prevent the oil from running out in an un-
controlled manner, hold a small metal chute under the
opening and collect the oil in a vessel. If the oil does
not drain out completely, we recommend tilting the
compressor slightly. When the oil has drained out, re
fit the oil drain plug (18).
Dispose of the old oil at a drop-off point for old oil.
To fill in the correct quantity of oil, make sure that the
compressor stands on an even surface.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Fill new oil through the oil filler opening (fig. 8 pos.
12.1) until it comes up to the maximum level. This is
marked with a red dot on the oil level window (18)
(Fig. 9 pos. 18.1). Do not exceed the maximum filling
quantity. Overfilling the equipment may result in dam-
age. Reinsert the oil sealing plug (fig. 8 pos. 12) into
the oil filler opening (fig. 8 pos. 12.1).
10.6 Cleaning the intake filter (Fig. 11, 12)
The intake filter prevents dust and dirt being drawn
in. It is essential to clean this filter after at least every
300 hours in service. A clogged intake filter will de-
crease the compressor's performance dramatically.
Open the thumb screw (G) to the remove the intake
filter.
Then pull off the fi lter cover (J). Now you can remove
the air filter (L) and the filter housing (K). Carefully tap
out the air filter, Filter cover and filter housing. Then
blow out these parts with compressed air (approx.
3 bar) and reinstall in reverse order.
10.7 Storage
m Important!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Switch
off the compressor and make sure that it is se-
cured in such a way that it cannot be started up
again by any unauthorized person.
m Important!
Store the compressor only in a dry location
which is not accessible to unauthorized persons.
Always store upright, never tilted!
10.8 Releasing excess pressure
Release the excess pressure by switching off the
compressor and using the compressed air which
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a blow-
out pistol.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Quick-lock coupling, intake filter
* Not necessarily included in the scope of delivery!

11. Disposal and recycling

The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic.
GB | 23