Reverse the door opening
If required, the door opening can be moved from the
right (supplied condition) to the left side.
WARNING:
When replacing the door stop, the appliance must be
disconnected from the power supply first.
NOTE:
You possibly need:
screw wrench, Phillips screwdriv-
er as well as a thin-blade screwdriver.
 Remove the blind cap (1) and the hinge cover (2).
 Loosen the screws (3), remove the door hinge (4)
and lift the appliance door.
 Move the blind plug (5) of the appliance door to
the opposite side. Set the door aside safely.
 Tilt the appliance slightly backwards and block it
in this position. Dismount the door hinge (6) with
its base by loosening the screws (7). Unscrew the
separate foot (8).
 Move and fasten the door hinge (6) incl. base with
the screws (7). Screw in the separate foot (8) ac-
cordingly.
 Put the appliance back in the upright position. Put
on the appliance door and fix it in the intended
position. Move and fasten the door hinge (4) with
the screws (3).
 Replace the hinge cover (2) and move the blind
cap (1) into the exposed hole.
Check that the door is optimally aligned both vertical-
ly and horizontally to ensure a smooth opening and
closing of the door.

Startup / Operation

Prior to first use
CAUTION:
After transport, the appliance should be left standing
upright for about four hours before connecting to the
power supply. Nonobservance could lead to malfunc-
tion of the cooling system and causes an appliance
breakdown.
Clean the appliance interior including all accessory
parts. Consider the instructions which we provide in
"Cleaning and Maintenance".
the chapter
Starting the appliance
 Connect the appliance to the power supply.
 Operate the temperature control. See also the
"Settings".
section
Settings
Setting [ OFF ] means that the appliance is in the off
state. Turn the temperature control clockwise, start-
ing from this setting; the appliance will turn on auto-
matically.
The power levels [ MIN – MAX ] regulate the different
values of the internal temperature.
Setting OFF: Off state
Power level MIN :
lowest level → warmest internal temperature
Temperature range approx. +6°C ∼ +8°C
Power level NORMAL :
medium level → optimal operating temperature
Temperature range approx. +4°C ∼ +6°C
Power level MAX* :
highest level → coldest internal temperature
Temperature range approx. +2°C ∼ +4°C
*Beware of high setting because the maximum level
may already means "freezing point".