Menu P4  Reading the temperatures
Submenu
Description
P41
Comfort temperature
P45
Current value of T1
(= outside air temperature)
P46
Current value of T2
(= supply air temperature)
P47
Current value of T3
(= return air temperature)
P48
Current value of T4
(= exhaust air temperature)
Menu P5  Setting additional programmes
Submenu
Description
P50
Activation of the open fi re programme.
P51
Confi rming the presence of
a Preheater element
Only change if a preheater element is installed afterwards or an general reset is given.
P52
Setting the Preheater programme.
• 0; Guaranteed protection.
• 1; High protection.
• 2; Nominal protection.
• 3; Economy.
In
GUARANTEED PROTECTION MODE
guarantee of balanced ventilation. Vice versa, in
last possible moment; balanced ventilation is not guaranteed in this mode.
When commissioning the ComfoAir, the Preheater programme can usually be left at level 2:
(factory setting). In areas with frequent cold spells in winter (frequent periods of -10°C or lower), level 1
should be selected:
P54
Confi rming the presence of a bypass.
The standard ComfoAir confi guration includes a bypass. Therefore, leave the value at '1'.
P56
Setting the required air volume in the house.
• nL: "normal air volume".
• HL: "high air volume".
Setting the air volume is the starting point for programming the air specifi cations and setting the fans.
P57
Setting the ComfoAir type.
• Li = "Left-hand version".
• Re = "Right-hand version".
With delivery the ComfoAir is correctly pre-programmed at the factory.
After an general reset the pre-programming is lost and the setting must be reset.
The right setting is mentioned on the identifi cation plate on top of the ComfoAir.
P58
Enter controller priorities.
• 0; The highest air setting is leading INCLUDING the
signals from the analogue inputs
• 1; The highest air setting is leading EXCLUDING the
signals from the analogue inputs
EN - 12
Minimum
12
C
o
-
-
-
-
the Preheater element is switched on soonest; this level offers the best
or even level 0:
HIGH PROTECTION
Temperature values
Maximum
28
C
20
o
o
-
Current
-
Current
-
Current
-
Current
Additional programme values
Minimum
0 (= No)
0 (= No)
0
the Preheater element switches on at the
ECONOMY MODE
.
GUARANTEED PROTECTION
0 (= No)
nL
Li
0
General
Reset
C
C
o
C
o
C
o
C
o
Maximum
General
Reset
1 (= Yes)
0
1 (= Yes)
0
3
2
NOMINAL MODE
1 (= Yes)
1
HL
HL
Re
Li
1
0