Mode
Explanation
Mode 4
The solar energy covers the heat
pump's/indoor module's/control module's
energy need*. Lit symbol. Selected meas-
ure(s) activated, sequence according to
operating prioritisation. If there is no need
according to operating prioritisation, the
AUX output is closed if it is set to photovol-
taic control. If AUX is to be routed, this
must be selected in menu 5.4 - AUX relay.
*If Prioritise domestic electricity is selected, considera-
tion is given to this in the first instance.
MENU 4.1.10 – SOLAR ELECTRICITY
In this menu, you make settings that are specific for
EME 20
For EME 20, you can select whether you want domestic
electricity to be prioritised ahead of room temperature
and hot water, provided that the main product is
equipped with an external energy meter (accessory).
AFFECT ROOM TEMPERATURE
Setting range: on/off
Factory setting: off
AFFECT HOT WATER
Setting range: on/off
Factory setting: off
AFFECT POOL TEMPERATURE
Setting range: on/off
Factory setting: off
EXTERNAL ENERGY METER
Setting range: X22/X23
Factory setting: --
PRIORITISE DOMESTIC ELECTRICITY
(EME 20)
Setting range: on/off
Factory setting: off
MENU 5.2.4 – ACCESSORIES
Activating/deactivating of accessories.
Select: photovoltaic control
MENU 5.4 – SOFT INPUTS/OUTPUTS
Activating/deactivating of accessories.
Select: if AUX is to be used for photovoltaic control
EME 20 F-series | GB

Technical data

TECHNICAL SPECIFICATIONS
EME 20
External; dimen-
mm
sions (LxWxH)
Enclosure class
Part no.
81x81x28
IP22
057 188
F
39