TIP
Wait 24 hours before making a new setting,
so that the room temperature has time to sta-
bilise.
If it is cold outdoors and the room temperature
is too low, increase the curve slope in menu
1.30.1 by one increment.
If it is cold outdoors and the room temperature
is too high, reduce the curve slope in menu
1.30.1 by one increment.
If it is warm outdoors and the room temperat-
ure is too low, increase the value in menu 1.1.1
by one increment.
If it is warm outdoors and the room temperat-
ure is too high, reduce the value in menu 1.1.1
by one increment.
MENU 1.3 - ROOM SENSOR SETTINGS
Here, you select the zone to which a sensor will belong.
It is possible to connect multiple room sensors to each
zone. Each room sensor can be given a unique name.
The control of heating, cooling, humidity and ventilation
are activated by ticking each option. Which options are
shown depends on which type of sensor is installed. If
control is not activated, the sensor will be the displaying
sensor.
Caution
A slow heating system such as underfloor
heating may be inappropriate for controlling
with room sensors.
MENU 1.30.7 - OWN CURVE
Own curve, cooling
Caution
Curve 0 must be selected for own curve to
apply.
You can create your own cooling curve here, if there are
special requirements, by setting the desired supply
temperatures for different outdoor temperatures.
Supply temp
Setting range: -5 – 40 °C
Depending on which accessory is used the setting range
can vary.
MENU 4.2.3 - SG READY
Affect cooling
With low price mode of "SG Ready" and cooling opera-
tion the indoor temperature is not affected.
HPAC S40 | GB
With overcapacity mode on "SG Ready" and cooling op-
eration, the parallel offset for the indoor temperature is
decreased by "-1". If a room sensor is installed and activ-
ated, the desired room temperature is decreased instead
by 1 °C.
MENU 4.2.5 - SMART PRICE ADAPTION™
Affect cooling
Alternative: on/off
Degree of effect
Setting range: 1 – 10
This function can only be used if your electricity supplier
supports Smart price adaption, if you have an hourly
tariff agreement and an active myUplink account.
Smart price adaption™ adjusts some of the heat pump's
consumption over the day to those periods with the
cheapest electricity tariff, which can give savings if on
an hourly rate based electricity contract. The function is
based on hourly rates for the next day being retrieved
via myUplink, and an Internet connection and an account
for myUplink are therefore required.
You can choose which parts of the installation are to be
affected by the electricity price and to what extent; the
higher value you select, the greater the effect the elec-
tricity price has.
NOTE
A value that is set high may result in increased
savings, but may also affect the comfort.
MENU 7.1.2.2 - PP SP. HEATING MEDIUM
GP1
Make settings here for the heating medium pump's
speed in the current operating mode, for example in
heating or hot water operation. Which operating modes
can be changed depends on which accessories are
connected.