INSTALLATION GUIDE
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c.
Install connecting bridges between the connection points 4-5. Uw groepen
moeten afgezekerd zijn met minimaal 16 A (3x). The connecting power
cable must have a minimum core cross section of 2,5 mm
You can use the bridges provided on the connecting block to make the
required interconnections as indicated in the preceding illustrations. How to
install the bridges is indicated in the junction box cover and in the
illustration below. The bridges should not be placed immediately on top of
the connecting wires, but between the screw-head and the clamp around the
connecting wire.
126
Secure the cable with the strain relief and close the cover.
electrical connection
2
.
INSTALLATION GUIDE

Cut opening in worktop

Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present.
The distance from the saw line to the rear wall and/or side wall is
indicated in the table.
Table
Type of hob
Appliance width x depth
575 x 505 mm
614 x 514 mm
774 x 514 mm
Installation height from top of worktop
56
44
Cut out dimensions width x depth
560 x 490 mm
750 x 490 mm
Distance from saw line to rear wall
Distance from saw line to side wall
Space to be left free around the appliance
cooker hood
min. 600 mm (HL60..G en HL60..M)
cabinet
min. 750 mm (HL70..M)
min. 650 mm
min. 450 mm
min. 40 mm
Ceramic hob
building in
HL60..G
HL60..M
HL70..M
x
x
x
x
x
x
x
x
x
50 mm
50 mm
50 mm
50 mm
70 mm
55 mm
127
min. 40 mm
side wall

Werbung