Herunterladen Inhalt Inhalt Diese Seite drucken

Extraordinary Maintenance - Gastrodomus MK225 Handbuch Zur Installation, Bedienung Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the breaks or damages research and moving elements unblocking
which can be performed from maintenance men.
TYPE
General Blackout
Net voltage
Fuses or magneto thermals intervention
lacking
place upstream of the machine feeding
line
Protection device intervention inside
Functioning
the machine
intervention
Cause/s not identifiable
The machine
Feeding voltage lacking.
doesn't
Sectioning devices set on "OFF".
function: the
Lacked running button functioning
blades don't
rotate or don't
Thermal intervention due to the overheating
perform
Visualization on the display of the letter "E"
correctly the
cutting

EXTRAORDINARY MAINTENANCE

For the intervention of extraordinary maintenance, consequent to breaks or revisions or mechanical and electric
damages, it is necessary an intervention request directly to the Authorized Assistance Center.
The instructions about the extraordinary maintenance don't appear in the present instruction manual for the use
and so must be explicitly requested to the manufacturer.
CLEANING
It is forbidden to clean by hand the organs and the elements in motion.
All cleaning interventions must be started only and exclusively, after having unloaded the machine with
the food product in working and having insulated from the electric feeding source and from
external energy. The machine, the electric equipment and the machine board components must not be
ever washed utilizing water, and not in any kind of jets form and quantity; so, without "bucket" nor "rubber" nor
"towel". Don't put ever directly the machine in the sink or under the tap.
The machine hygiene level classification and the associated equipment, for the foreseen use, are 2 (two): machine
that, after a hygiene risk evaluation, is in conformance with applicable international standards requirements, but requests
a programmed disassembly for the cleaning.
FREQUENCY
PERSONNEL
At the end of
Operator
every shift
work and
however
before the
daily use
24
POTENTIAL/S CAUSE/S
All the surface and the machine parts destined to come in contact with the food product or with
the food zones (tools external and internal surface) and the jets zones (tool superior surface
connected with the machine and machine external surface), must be cleaned and disinfected with
the under reported modalities. For the grinding group disassembly activities see the previous
descriptions.
- Scrape the surfaces from the possible food product residuals (for example with plastic
scrapers).
- Clean all the food zone surfaces and jets zone with a morbid dampened clothes (not
draining) with detergent diluted in hot water (also common soap for dishes is good). Don't
soak them. With a towel clean inside the grinding mouth. Use specific products for steel,
which must be liquids (not in cream or pastries however abrasive) and above all must not
contain chlorine. Against the fat substances the denatured alcohol.
- Rinse with cleaned hot water and successively dry all food zone surfaces and jets zone with
soft clothes that don't lose coats.
- The mixer tool, being in stainless steel, cannot be washed in dishwasher, much less the plastic
parts.
- The reassembly must happen only following working requirements, leave the pieces wrapped
up in soft dry clothes that don't lose coats.
PERIODS OF LONG INACTIVITY
- During the machine long inactivity periods provide to pass vigorously on all steel surfaces
(especially if stainless) a clothes soaked of Vaseline oil so that to spread a protective veil.
THINGS NOT TO DO BEFORE OR DURING THE CLEANING:
- enter towards the moving elements without to be previously checked of their stop;
- enter towards the moving elements without have stopped it in safety stop (blockage in zero
position of the electric feeding sectioning devices)
MODALITY AND COMPARISON
Contact the electric energy distributor
After having eliminated the causes that have determined the
protection device intervention, restore it. In case of problem
persistency contact an electrician technician.
Contact an electrician technician: after having eliminated the causes
that have determined the protection device intervention, restore it.
Contact directly the Authorized Assistance Center
Check and restore the electric energy
Connect the plug on the feeding socket
Check the button efficiency and eventually contact directly the
Authorized Assistance Center.
Wait the complete cooling before to machine restarting
Speed reader damaged, contact directly the Authorized Assistance
Center
MODALITY
ORIGINAL INSTRUCTIONS TRANSLATION

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis