Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Causes Of Failure - Scheppach HCE1450 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14. Possible causes of failure

Fault
High-pressure cleaner does not run.
High-pressure cleaner does not
output water.
Device has no pressure.
Heavy pressure fluctuations.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Possible cause
On/off switch (5) switched off.
Damaged mains cable (2).
Air trapped in the high-pressure
cleaner.
Water supply line pressure drop.
Nozzle (16/17) dirty.
Remedy
Switch on On/off switch (5).
Check mains cable (2) and have it replaced
by an electrician if necessary.
Switch on the high-pressure cleaner and
actuate the spray gun (10).
Check the water supply.
Clean nozzle (16/17) with the nozzle cleaning
needle (15).
GB | 23