34/124
Terminal strips for mains connection
.1
.3
.1
1
2
.2
.4
.2
Fig. 7: X1N4 voltage selection terminals (SB356) with connection groups G1, G2, G3
Table 2: Voltage selection terminals
Pin Signal Description/
function
1
PE
PE wire
L1 mains
2
L1
connection
L2 mains
G1
3
L2
connection
L3 mains
4
L3
connection
L1 mains
5
L1
connection
L2 mains
G2
6
L2
connection
L3 mains
7
L3
connection
L1 mains
8
L1
connection
L2 mains
G3
9
L2
connection
L3 mains
10
L3
connection
L1 device
11
L1
connection
L2 device
G4
12
L2
connection
L3 device
12
L3
connection
Bosch Rexroth AGSB356 | 3 609 929 B67/2008-11
.1
.1
.1
.1
3
4
5
6
.2
.2
.2
.2
G1
G2
Voltage/
current
PE potential
380 V~ -
415 V~/4.6 A
380 V~ -
415 V~/4.6 A
380 V~ -
415 V~/4.6 A
440 V~-
480 V~/3.9 A
440 V~-
480 V~/3.9 A
440 V~-
480 V~/3.9 A
500 V~/3.5 A
500 V~/3.5 A
500 V~/3.5 A
230 V~/7.5 A
230 V~/7.5 A
230 V~/7.5 A
Device connection
.1
.1
.1
.1
7
8
9
10
11
.2
.2
.2
.2
G3
The X1N4 interface partitions represent a
logical separation of the 3 possible mains
connection groups (G1 to G3).
A screwdriver with a 2 mm blade can be used
as a wiring tool.
WARNING!
Only the voltage selection terminals for the
G1, G2 and G3 groups are intended for
assignment of the mains connection. The
device connection may not be assigned.
WARNING!
Only the connections of one group may be
used. Do not use more than one group at
the same time.
Failure to adhere to this may lead to the
destruction of the device.
WARNING!
As the pin assignment (Table 2) indicates,
the mains must always be connected to the
upper terminal strip.
The lower terminal strip must remain fully
wired.
}
.1
.1
.1
12
13
.2
.2
.2
G4

Quicklinks ausblenden: