General notes on damages to property and products
2.2
Supplement for qualification of personnel
Use of non-qualified personnel!
Reduction of personal / plant safety, malfunctions / functional restrictions
possible!
Installation and service work for the coolant-technical part must only be
performed with the welding timer in a de-energized state.
The assembly of the cooling circuit and the plant may only be carried out
by qualified personnel.
3
General notes on damages to property and
products
For general notes on damages to property and products, refer to Table 1:
Required and supplementary documentation Rexroth PSI6xxx Weld Timer with
Medium-Frequency Inverter/ PRC7000 Process Resistance Control / PSG xxxx
MF welding transformers Instructions and Rexroth Weld Timer Safety and user
information.
4
Scope of delivery
For scope of delivery refer to Table 1: Required and supplementary
documentation Rexroth PSI6xxx Weld Timer with Medium-Frequency Inverter /
PRC7000 Process Resistance Control / PSG xxxx MF welding transformers
Instructions.
5
Cooling circuit
5.1
Closed and open cooling circuit
Due to its good heat transmission properties, water is the most frequently used
thermal transfer medium for temperature control systems in the cooling water
circuit. Water is found in a large variety of compositions and is in most cases not
suited for closed cooling circuits without special treatment. Contaminations in the
circuits or corrosion on tools lead to a deterioration of the heat transfer and thus
to a performance reduction.
Totally clogged circuits prevent temperature control. The causes for this are:
Dissolved minerals are converted to solid particles, e.g. calcium.
increase
Oxygen in the water
especially
in the tools.
R911370699 | PS6000/PRC7000 with water cooling
WARNING
the
aggressiveness and leads to
corrosion,