5.3.5

SETUP menu

The BENNING MM 12 offers individual setting possibilities. To change a setting, use
the Cursor key 7 to select the "SETUP" menu. Press the ENTER key 8 (up/ ▲) to
open the „SETUP" menu. Use the Cursor key 7 to choose between the following
settings:
APO
bL it
bEEP
A.Hold
Cnt in
diGit
TEMP
RESET
Pressing the CANCEL key 8 (down/ ▼) switches the instrument back to normal
operating mode.

5.4 Data logger function "LOG"

The data logger function "LOG" allows the automatic storage of series of measurements with
a predefined measuring interval and up to 40,000 measured values. The measuring interval can
be set from 1 s to 600 s. For further processing, the measured values can be read out later by
means of the display 1 , the optical interface P or via Bluetooth
Use the Cursor key 7 to select the "LOG" function and press the ENTER key 8 (up/ ▲) to
open the "LOG" menu.
Use the Cursor key 7 to select the following submenus:
SAVE
Press the ENTER key 8 (up/ ▲) to start the data logger function "LOG".
Pressing the ENTER key 8 (up/ ▲) again interrupts the measurement. Press
it again to continue measuring. Press the CANCEL key 8 (down/ ▼) to cancel
the function.
Note:
Any restart will delete all measured values stored in the data logger (LOG).
LOAD
Press the ENTER key 8 (up/ ▲) to open the measured values stored in the data
logger. Use the Cursor key 7 (up/ ▲, down/ ▼) to call the stored measured
values including their storage location number on the display 1 . Press the
CANCEL key 8 (down/ ▼) to cancel the function.
CLR
Press the ENTER key 8 (up/ ▲) to delete all measured values stored in the
data logger (LOG).
RATE
Press the ENTER key 8 (up/ ▲) to set the sampling rate defining the time
interval between two measuring points. Use the Cursor key 7 to adjust the
sampling from 1 s to 600 s.
The deviation of the timer is less than 3 s per hour.
MAX
Press the ENTER key 8 (up/ ▲) to open the maximum value of a series of
measurements stored in the data logger.
MIN
Press the ENTER key 8 (up/ ▲) to open the minimum value of a series of
measurements stored in the data logger.
The measured values stored in the data logger can be read out and stored as MS Excel
means of the enclosed PC software BENNING PC-Win MM 12.

5.5 Memory function "MEM"

The memory function "MEM" allows the automatic and manual storage of series of
measurements with up to 1,000 measured values. For further processing, the measured values
can be read out later by means of the display 1 , the optical interface P or via Bluetooth
Use the Cursor key 7 to select the "MEM" function and press the ENTER key 8 (up/ ▲) to
open the "MEM" menu.
Use the Cursor key 7 to select the following submenus:
12/ 2018
Automatic switch-off:
LC display illumination:
Acoustic signal:
Automatic storage of measured values: ON or OFF
Limiting value of continuity test:
number of digits of the LC display:
Unit of temperature
Factory settings:
BENNING MM 12
1 minute to 30 minutes or OFF
Auto (automatic), ON or OFF
ON or OFF
10 Ω to 50 Ω
Lo (low) or Hi (high)
°C or °F
YES, confirm with ENTER 8 (up/ ▲)
.
®
file by
®
.
®
26