6 Connection and commissioning
6.4.2.2
Variant 2
The GEL 211C is integrated into an existing network without a DHCP server or con-
nected directly to a terminal (point-to-point connection).
The GEL 211C is ready; the "Power" LED illuminates green.
Integrating the GEL 211C into an existing network without a DHCP server
 Connect the GEL 211C to a spare USB port on a Windows PC.
The GEL 211C is detected by the PC as mass storage and as a virtual COM port.
Should the GEL 211C not be detected as a virtual COM port, it may be
necessary to install a driver. You will find the related files on the newly de-
tected mass storage device in the folder driver.
 Start the commissioning tool
 Clear "DHCP client enable".
 Enter the IP address (Device IP address) and the subnet mask (Subnet mask).
 Eject the USB medium on the PC and disconnect from the USB port.
 Integrate the GEL 211C into the existing network using a suitable LAN cable.
 Open the web browser and start the web interface by entering the IP address.
If you cannot establish a connection, contact your network administrator.
90
Establishing network connection
(→ page
126).