On setting up a new record a window for entering the data appears where you can
make the following entries:
Window for entering a new record
Designa-
Name for the record saved in the GEL 211C
tion
Idleness
Rotational speed up to which standstill is still recorded (range 1, blue)
Overspeed Maximum rotational speed allowed (range 7, red)
Delay
Time in ms during which a range change is ignored
Hysteresis Rotational speed ranges referred to the lower range limit (ranges 2 to 7),
within which minor, brief (→ delay) fluctuations in the rotational speed are
ignored; left: coming from higher rotational speeds, right: vice versa
B
7
6
H
R
H
5
L
Bz
6
5
Example hysteresis (B= range, Bz= operating hours counter in the range, t
H
/H
= hysteresis left/right, n= rotational speed, t
L
R
GEL 211CS0
Spindle histogram group
t
<
V
7 Functions of the GEL 211C
Editing a record entry
t
t
>
>
V
V
= operating time recorded)
n
n
t
t
n
= delay,
V