8 Troubleshooting
No.
Error message
E0401
Timeout – no spin de-
tected.
E0403
File system error
E0404
Memory overflow: too
many samples. The tar-
get wheel spin was too
slow.
E0405
Memory underrun: too
few samples. The target
wheel spin was too fast.
E0407
No reference signal de-
tected
E0408
Dongle error
E0409
Phase error excessively
large for automatic cali-
bration
E040A
Reference signal
present even though
measurement should
be undertaken without
reference signal
E040B
It was not possible to
send thresholds
E040D
Feature is not support-
ed by the MiniCODER
E040E
Error during the com-
munication with the
MiniCODER
118
Error table
Cause
No MiniCODER con-
nected
Target wheel does not
turn
Faulty reference sig-
nal
Memory error
Speed of target wheel
too low
Speed of target wheel
too high
Reference signal not
connected or voltage
level not ok
MiniCODER was pro-
grammed using a cus-
tomer-specific
GEL 211 and cannot be
programmed using this
device.
Wrong MiniCODER or
wrong target wheel
mounted
Manual entry of number
of teeth
Communication errors
Communication errors
Lenord+Bauer
Remedy
Check/correct measur-
ing set-up, retry analysis
Repair necessary: send
device back to the facto-
ry
Increase speed of target
wheel
Decrease speed of tar-
get wheel
Check reference signal
and voltage level
Program MiniCODER
using the customer-spe-
cific GEL 211
Replace MiniCODER
and/or target wheel
– Check mounting posi-
tion
– Disconnect reference
signal
Check connection
Check connection