Herunterladen Inhalt Inhalt Diese Seite drucken

NITEHOG PYTHON Bedienungsanleitung Seite 64

Wärmebild beobachtungsgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TYPICAL FAULTS AND
No.
EXTERNAL SIGNS
The panel buttons do
5
not function
The Auto NUC is not
6
working
The ZOOM is not
7
working
The image on the
8
display is blurred and
out of focus
There are fewer or no
details in the image
9
and there is too much
exposure of the object
The scene background
10
is too dark
11
The image is too dark
64
THEIR
POSSIBLE CAUSES
Electronics boot failure
Electronics malfunction
External NUC mode is
selected
Shutter is stuck
Electronics boot failure
Electronics malfunction
Device is not focused on
the observed distance
The eyepiece/collimator
back lens are dirty
Opto-mechanical mal-
function
Contrast level is high
Low Contrast level
Low Brightness level
Low Luminance level
Low Brightness level
POSSIBLE
SOLUTIONS
Restart the device
Return the device for
maintenance
Switch to internal NUC
and press N button
Return the device for
maintenance
Restart the device
Return the device for
maintenance
Focus on the target
object
Clean the collimator
lens
Return the device for
maintenance
Decrease Contrast
level
Increase Contrast level
Increase Brightness
level
Increase display
Luminance level
Increase Briaghtness
level

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für NITEHOG PYTHON

Inhaltsverzeichnis