TYPICAL FAULTS
No.
AND THEIR
EXTERNAL SIGNS
When the
device is turned
1
on there is no
image on the
screen
The image
of the area
2
is weak and
foggy
The image
is smudged/
3
negative like
image
The image is
4
smeared or
grainy
POSSIBLE CAUSES
Poor contact with the
batteries
Wrong polarity
Depleted battery
Screen brightness is set to
minimum
Problem with the battery
cap
Display problem
Detector problem
Contamination over
the external surfaces of
the objective and/or the
eyepiece/collimator
Contamination
internal surfaces of the
objective
and/or
eyepieces
NUC is on external mode
NUC mechanism is stuck
Wrong weather type or
image filter is selected

TROUBLESHOOTING

TROUBLESHOOTING
Check batteries and
battery compartment
contacts and clean them,
if necessary with the
cleaning cloth. Replace
or recharge the batteries
Adjust the brightness
through the menu
Replace the battery cap
Return the device for
maintenance
Clean all external surfaces
with a napkin or the
LensPen
of
the
Return the device for
maintenance
the
Put the objective cap on
and press the N button
or switch to internal NUC
and press the N button
If on internal NUC the
mechanics do not move
when pressing the
N button, return the
unit to the factory for
maintenance
Try other image filters or
weather types until you
reach the desired image
appearance