TYPICAL FAULTS
No.
AND THEIR
EXTERNAL SIGNS
When the
device is turned
1
on there is no
image on the
screen
The image
of the area
2
is weak and
foggy
The image
is smudged/
3
negative like
image
The image is
4
smeared or
grainy
POSSIBLE CAUSES
•
Poor contact with the
batteries
•
Wrong polarity
•
Depleted battery
•
Screen brightness is set to
minimum
•
Problem with the battery
cap
•
Display problem
•
Detector problem
•
Contamination over
the external surfaces of
the objective and/or the
eyepiece/collimator
•
Contamination
internal surfaces of the
objective
and/or
eyepieces
•
NUC is on external mode
•
NUC mechanism is stuck
•
Wrong weather type or
image filter is selected
TROUBLESHOOTING
TROUBLESHOOTING
•
Check batteries and
battery compartment
contacts and clean them,
if necessary with the
cleaning cloth. Replace
or recharge the batteries
•
Adjust the brightness
through the menu
•
Replace the battery cap
•
Return the device for
maintenance
•
Clean all external surfaces
with a napkin or the
LensPen
of
the
•
Return the device for
maintenance
the
•
Put the objective cap on
and press the N button
or switch to internal NUC
and press the N button
•
If on internal NUC the
mechanics do not move
when pressing the
N button, return the
unit to the factory for
maintenance
•
Try other image filters or
weather types until you
reach the desired image
appearance
POSSIBLE
SOLUTIONS
EN
EN
63