Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Starting The Equipment - EINHELL BT-GW 911D Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Anleitung_BT_GW_911_D_SPK7__ 28.11.14 08:19 Seite 20
GB
Important information about the power
connection
This equipment falls under Class A of the standard
EN 60974-10, i.e. it is not designed for use in
residential areas in which the power supply is based
on a public low-voltage supply system because given
unfavorable conditions in the power supply the
equipment may cause interference. If you want to use
the equipment in residential areas in the which the
power supply is based on a public low-voltage supply
system, you must use an electromagnetic filter which
reduces the electromagnetic interference to the point
where the user no longer notices any disturbance.
In industrial parks or other areas in which the power
supply is not based on a public low-voltage supply
system the equipment can be used without such a
filter.
General safety information
It is the user's responsibility to install and use the
equipment properly in accordance with the
instructions issued by the manufacturer. If
electromagnetic interference is noticed, it is the user's
responsibility to eliminate said interference with the
technical devices mentioned in the section "Important
information about the power connection".
Reduction of emissions
Main current supply
The welder must be connected to the main current
supply in accordance with the instructions issued by
the manufacturer. If interference occurs, it may be
necessary to introduce additional measures, e.g.
fitting a filter to the main current supply (see above in
the section "Important information about the power
connection"). The welding cables should be kept as
short as possible.
Pacemakers
Persons using an electronic life support device (e.g. a
pacemaker) should consult their doctor before they
go near electric sparking, cutting, burning or spot-
welding equipment in order to be sure that the
combination of magnetic fields and high electric
currents does not affect their devices.
For commercial users the guarantee period is 12
months and for normal users 24 months, beginning
from the date of purchase.
20

4. Technical data

Mains connection:
Welding current:
Duty cycle X%:
10 15 25 35 60 100
Welding current I
(A):
2
400 V:
160 130 100 85 65
230 V:
/
Rated idling voltage U
:
0
Max. welding wire drum:
Welding wire diameter
Fuse:
Weight:
The welding times apply for an ambient temperature
of 40° C.

5. Before starting the equipment

5.1 Assembly (Fig. 5-21)
5.1.1 Installing the castors and guide rollers
(6/14)
Install the castors (6) and guide rollers (14) as shown
in Figures 7, 9, 10 and 11.
5.1.2 Fitting the welding screen (17)
Place the welding glass (l) and the transparent
safety glass (m) over it in the frame for the safety
glass (k) (Fig. 12).
Press the safety glass retaining pins (q) into the
holes in welding screen frame (s) from the
outside. (Fig. 13)
Place the frame for the safety glass (k) with the
welding glass (l) and transparent safety glass (m)
from the inside into the recess in the welding
frame (s), press the safety glass retaining
bushes (n) on to the safety glass retaining pins
(q) until they engage to secure the frame for the
safety glass (k). The transparent safety glass (m)
must be on the outside. (Fig. 14)
Bend the top of the welding screen frame (s)
inwards (Fig. 15/1) and fold down the top corners
(Fig. 15/2) Now bend the outer sides of the
welding screen frame (s) inwards (Fig. 15/3) and
connect them by pressing the top corners and
outer sides together. As the retaining pins
engage, you should be able to hear to clear
clicks on each side (Fig. 15/4).
When the top corners of the welding screen are
230 V/400 V ~ 50 Hz
25-160 A (max. 190 A)
/
115 90 70 60 40 25
41 V
5 kg
0.6/0.8/1.0 mm
16 A
36,3 kg

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis