Herunterladen Inhalt Inhalt Diese Seite drucken

Symbols And Technical Data - EINHELL ISG 1000/1 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ISG 1000/1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Anleitung ISG 1000_1_SPK1:Anleitung ISG_1000_1_SPK1
Safety clothing
1. While working, the welder must protect his entire
body from radiation and burns by wearing
suitable clothing and a face guard.
2. Slip-on gloves made of a suitable material
(leather) must be worn on both hands. They
must be in perfect condition.
3. Suitable aprons must be worn to protect clothing
from sparks and burns. A safety suit and, if
necessary, head protection must be worn if
required by the type of work in question, e.g.
overhead welding.
4. The protective clothing used as well as all
accessories must be in compliance with the
"Personal safety equipment" EU Directive.
Protection from radiation and burns
1. Provide information about the risk to eyes at the
working site in the form of a poster with the
wording "Caution – do not look at the flames".
Workplaces are to be screened off wherever
possible so that personnel in the vicinity are
protected. Unauthorized persons are to be kept
away from the welding work.
2. The walls in the immediate vicinity of stationary
workplaces should not have a light color or a
sheen. Windows up to head height are to be
protected against radiation passing through them
or reflecting off them, for example by coating
them with a suitable paint.

4. SYMBOLS AND TECHNICAL DATA

EN 60974-1
European standard for welding
sets for manual arc welding with
limited on time.
Single-phase static frequency
1~
f
1
f
2
converter transformer rectifierr
50 Hz
Mains frequency
U 1
Mains voltage
I max
Rated maximum mains current
Fuse with rated value in A
U 0
Rated idling voltage
15.05.2007
I 2
Welding current
Ø mm
Electrode diameter
Symbol for falling characteristic
curve
Symbol for manual arc welding
with sheathed rod electrodes
Single-phase mains connection
Do not store or use the
appliance in wet or damp
conditions or in the rain.
Thoroughly read and understand
the operating instructions prior to
using the welder.
IP 21
Protection type
H
Insulation class
X
On-load factor
The set is interference-suppressed in compliance
with EC Directive 89/336/EEC.
The product meets the requirements of EN 60974-
10, class A, meaning that it may only be used for
industrial applications. In unfavorable conditions the
product can cause electromagnetic interference.
Mains connection
230 V ~ 50 Hz
Welding current
10 - 80 A
On-load factor X
15%
60%
100%
Idling voltage (V)
Power input
2500 VA at 80 A
Fuse (A)
Weight
5. Fitting the carrying strap (Fig. 3/4)
Attach the carrying strap (11) as shown in Fig. 3/4.
8:38 Uhr
Seite 11
GB
80 A
40 A
35 A
85
16
5 kg
11