15 Technical data

15.1 MAXIMUS MPX SERIES2
(MPXHD)

15.1.1 General

AISI 316L stainless steel construction
External surfaces micro-shot peened and electro-
polished
Dynamic positioning control system

15.1.2 Mechanical

Cable inputs: 2 x 3/4" NPT
Zero backlash
Horizontal rotation: 360°, continuous rotation
Vertical rotation: from -90° up to +90°
Horizontal speed (variable): from 0.1° to 100°/s
Tilt speed (variable): from 0.1° to 100°/s
Accuracy of preset positions: 0.02°
Integrated wiper
Window with extra clear tempered glass: thick 12mm
(0.47in)
Unit weight: 26.5kg (58lb)

15.1.3 Electrical

Supply voltage/Current consumption:
• 230Vac ±10%, 0.5A, 50/60Hz
• 24Vac ±10%, 5A, 50/60Hz
• 120Vac ±10%, 1A, 50/60Hz
• 220Vac ±10%, 0.54A, 50/60Hz
• 100Vac ±10%, 1.2A, 50/60Hz
Power consumption:
• 120W max
MNVCMPXHDC_2038_EN

15.1.4 Network

RJ45 port
• Ethernet connection: 10BASE-T/100BASE-T
Slot SFP (SMALL FORM FACTOR PLUGGABLE)
• Ethernet connection:100BASE-FX
• Supply voltage: 3.3V
• Standard: compliant MSA
The SFP module (not supplied by VIDEOTEC) must
meet the following requirements:
• Laser: Class 1, complies with EN60825-1
• Certification: UL/IEC 60950-1 or UL/IEC 62368-1

15.1.5 I/O interface

Input for remote reset: 1
Alarm inputs: 1
Relay outputs: 1+1 (1 relay reserved for washer pump
and one configurable, 1A, 30Vac/60Vdc max)

15.1.6 Video analytics

Ultra-robust detection algorithms and auto-tracking,
specifically for outdoor perimeter control.
Targets Classification: People, vehicles, generic
objects
Programmable rules for video analysis, VIDEOTEC
ANALYTICS (it is possible to rapidly configure up to
ten rules for every preset using an intuitive control
management interface)
• Line crossing: the target triggers an alarm if it
crosses the line in one or both directions
• Entering/leaving area: the target triggers an alarm
if it leaves or enters the configured area
• Appearing in area: the target triggers an alarm if it
appears inside the configured area
• Loitering: the target triggers an alarm if it stays
inside the configured area over the set time
Detection Mask: disables the detection activity in a
portion of the image to prevent false alarms
Video Tampering Detection: a specific ONVIF alarm is
triggered if the video camera view is obstructed (e.g.
spray)