Herunterladen Inhalt Inhalt Diese Seite drucken

Connection - HBM RM4220 Bedienungsanleitung

Dms--verstärker
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RM4220
3

Connection

The connection of the amplifier and the connection of the voltage supply take
place by four peelable connectors. Individual wires can be clamped in a range
2
of 0,13 mm
... 1,5 mm
should be used to connect the cores to the terminals. Cores with or without
end sleeves must not be tin--plated.
The 4 connectors are labeled with numbers, so they can inserted in the 4 sok-
kets with no danger of a mix--up.
The subsequent figures give the respective connection diagrams that are prin-
ted onto the housing cover.
For 4- -wire technique (factory setting)
Typ
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A1091--21 de/en
2.
End sleeves (without plastics hoop, length 10 mm)
Function
Measuring signal (-)
Screen
Bridge excitation voltage (+)
Measuring signal (+)
Bridge excitation voltage (--)
Supply voltage (V+)
Output voltage
GND = Ground
GND = Ground
Current output
Ground
RM4220
Color (HBM -- cable
4--wire technique)
RD (red)
BU (blue)
WH (white)
BK (black)
31