5.3.2
Timing diagram with premature door opening
Latch_In
Option 2
Override delay
Flush position
Safety circuit
Latch_Out
Active
Protection field
Inactive
Active
: Light curtain interruption actuates an emergency stop
Inactive : Light curtain interruption has no effect
Figure 3:
Timing diagram (premature door opening)
5.3.3
Timing diagram without premature door opening
Latch_In
Option 2
Override delay
Flush position
Safety circuit
Latch_Out
Active
Protection field
Inactive
Active
: Light curtain interruption actuates an emergency stop
Inactive : Light curtain interruption has no effect
Figure 4:
Timing diagram (without premature door opening)
8
Zone
Slow
Stop
ON
Zone
Slow
ON
Stop
Zone
Drive
OFF
Driving
release
Zone
OFF
Drive
Driving
release