Connection configuration

Important safety notice:
The units should only be connected when de-energized!
K1 - K2
Emergency stop alarm detector
K3 - K4
Contact
feedback
contactor. These connections should be
bypassed if an external contactor is not
used.
K5 - K6
Contact feedback for external safety circuit
contactor. These connections should be
bypassed if an external contactor is not
used.
K7
Internal call signal 1, 12 ... 265 VAC / DC
K8
Internal call signal 2, 12 ... 265 VAC / DC
K9
Internal call signal 3, 12 ... 265 VAC / DC
K10
Internal call signal 4, 12 ... 265 VAC / DC
K11
Internal call signal 5, 12 ... 265 VAC / DC
K12
Internal call signal 6, 12 ... 265 VAC / DC
K13
Internal call signal 7, 12 ... 265 VAC / DC
K14
Internal call signal 8, 12 ... 265 VAC / DC
K15
Internal call signals, common potential
K16 - 17
Option 1 (not used)
K18 - 19
Option 2, 12 ... 380 VAC / DC*
K20 - 21
Flush position, 12 ... 380 VAC / DC*
K22 - 23
Override delay
12 ... 380 VAC / DC*
K24 - 25
Latch In, 12 ... 380 VAC / DC*
K26 - 27
Latch Out (Relay-closing contact)
K28 - 29
Safety circuit 1: The circuit is closed if no
error is evident and the system has been
started ("Safety circuit LED" illuminates),
isolated.
K30 - 31
Safety circuit 2, otherwise as safety circuit 1
K32, K33
230 VAC, phase / PEN conductor
K34
Protective earth
*Note polarity when actuating with direct voltage (see
also Chapter 5.4)

SAFETY ADVICE

Overcurrent protection shall be provided
according to DIN EN 60204-1:2019-06 (see
chapter 7).
The electrical equipment shall be wired
according to DIN EN 60204-1:2019-06.
© CEDES | V 2.8
for
external
latch
Figure 10:
Connection terminals plug-in system controller
English
11