14. Technical data

General data
Unit type
Safety classification
No. of entrances
to be monitored
Norm conformity
1
Optical
Operating range
Max. operating range
according to EN 61496-1
Active safety height
4
No. of light beams
3
Emitter / receiver aperture
angle
Light reserve after calibration Approx. 100%
Max. ambient light
Mechanical
Opto edge
- Cross-section (W × D)
- Length
System control rack
- Dimensions (W × D × H)
- Weight
Enclosure rating
- Opto edges
- Control unit light curtain
Temperature range
- cegard/Lift LX/LY
- cegard/Lift LX/LY - IP67
1
With consideration being given to the relevant instructions in these
operating instructions and relevant regulations.
2
Ensure that suitable interference suppression is provided
(interference fuse via contactor coil) when using external load
contactors. In addition, the load contactor should have positive-
action contacts with auxiliary contact and meet the requirements
of respective regulations in EN 81 and along with other national
regulations (type testing).
24
Light curtain system, with
integrated testing, for
safeguarding passengers in lifts
without cabin door
EN 61508 SIL 2 and
EN ISO 13849-1 Cat. 2 / PL d
1 or 2 (through-loading
elevators)
EN 61508:2010
EN ISO 13849-1:2015
EN 61496-1:2013
EN 61496-2:2013
EN 62061:2005 + Cor.:2010
+ A1:2013 + A2:2015
DAFA 74B:2018
0.7 ... 4 m or 4 ... 8 m
1 m
3
1,630 mm
(other protection
heights are optionally available)
46 (optional 70)
40°
Acc. to IEC 61496-2
14 mm × 17 mm
1,730 mm
(other protection
heights are optionally available)
318 × 342 × 201 mm
6 kg
IP65
IP54
+10° ... +65°C
–20° ... +65°C
Electrical
Supply voltage U
SP
Current input
Fuse supply voltage
Fuse safety circuits
Outputs
Safety circuit
Safety circuit load capacity
With external load contactors
Latch circuit
LX latch circuit load capacity 230 VAC / 16 A, 3*380 VAC
LY latch circuit load capacity 230 VDC / 2 A resistive load
- "Alarm" output
- HIGH
- LOW
Reaction time of outputs
Inputs
Internal call signals
Logical voltage range (HIGH) 12 ... 265 VAC / DC
Logical voltage range (LOW)
Input current
Service button
Automatic start
Latch-In, flush position,
Override delay, option 2
Logical voltage range (HIGH) 12 ... 380 VAC / DC
Logical voltage range (LOW)
Reaction time to signal
change
Input current
3
To achieve the maximum angle of radiation allowed, either the
100 847 or the 100 848 mounting kit is required.
4
Depending on specification, other opto-edge lengths are possible
on request. Please contact CEDES for more information.
English
195 ... 265 VAC,
50 ... 60 Hz
< 100 mA at 230 VAC
100 mAF
2 x 4 AF
Relay contacts
(2-channeled) with restart
inhibitor
230 VAC / 4.0 A
resistive load
2
Depends on load contactor
used
Relay contactor (single-
channeled) with check test
/ 16 A resistive load
24 V / 100 mA, for
connecting alarm detector
Emergency stop activated,
safety circuits interrupted
No emergency stop
< 150 ms, typ. 100 ms
8 inputs, isolated, polarity
irrelevant with DC for
resetting an alarm and
testing no safety circuit
drop-out during double and
multiple starts
0 ... 5 VAC / DC
(see Chapter 8)
Approx. 1 mA
On control unit light curtain
for inspection purposes
After power-up test
Isolated, note polarity
with DC
0 ... 5 VAC / DC
(see Chapter 8)
Approx. 100 ms
Approx. 1 mA