This bracket is used when the people/object detection
takes place too close to the elevator door i.e. the person or
object is detected too late.
The bracket also reduces the mounting height of the
sensor. This is useful when there is insufficient space in
the transom for the whole sensor. To mount the 5 degree
bracket the same mounting holes of the flush mounting kit
can be used.
5.6.1 Exchanging the bracket
1. Remove the optical cover by sliding it over the
mounting plate to the side (away from the cable outlet).
2. Remove the mounting plate by lessening the four
screws.
3. Replace the existing bracket with the 5 degree one.
4. Re-install the mounting plate using the four screws.
5. Place the optical cover back in place:
 Position the optical cover to the right of the mounting
plate (1).
Optical cover
Figure 23:
Positioning of the optical cover
(ferrite core on cable not displayed)
 Carefully press down on the left side of the cover (2)
and slide it from left to right (3). The cover is correctly
mounted when it is centered and cleanly locked in
position.
Optical cover
2
3
Figure 24:
Optical cover - press (2) and slide (3)
(ferrite core on cable not displayed)
© CEDES | V 4.0
1
5 degree bracket
with fixing plate
IMS 100 Pro sensor
5 degree bracket
with fixing plate
IMS 100 Pro sensor
5.7

If needed - removal of expanding rivets

Use a small slot screwdriver as shown to remove the
expanding rivets from the mounting bracket (Figure 25).
The rivets can be reused.
Figure 25:
Removing the rivets
6.

Electrical installation

Make sure that the power supply voltage available for the
IMS 100 Pro is +24 VDC ±20%. The power supply has to
provide at least 250 mA for proper operation.
6.1
Cable and electrical connection of
IMS 100 Pro
Cable color
Connected to
Brown
U
SP
Blue
GND (0 VDC)
Black
Output (Door re-open signal)
White
U
SP
C
Figure 26:
Electrical connection IMS 100 Pro
6.2

Output logic

U
SP
Output
0 V
Status
No object
Output
24 VDC
HIGH
Red LED
OFF
Figure 27:
Output logic IMS 100 Pro
= 24 VDC ±20%
(Timeout selected)
U
(brown)
SP
Output (black)
Load
i
PNP
GND 0 VDC
(blue)
U
(Timeout
SP
selected - white)
Object
Door mode
detected
0 VDC
24 VDC
LOW
ON
Blinking