Sawing on a slope (Fig. K)
When sawing on a slope, make sure you always
stand higher than the tree trunk (Fig. K). In order to
maintain complete control at the moment of "sawing
through", reduce pressure towards the end of the
cut without releasing your tight grip on the handles
of the chainsaw.
Warning!: The saw chain must not come in contact
with the ground.
After completing the cut, wait for the saw chain to
come to a standstill before removing the chainsaw.
Always turn off the chainsaw's motor when going
from one tree to the next.

10. Maintenance

Always pull the plug out of the power socket before
doing any work on the chainsaw!
• Keep the cooling vents on the motor housing clean
and unobstructed at all times.
• Only the maintenance work described in these op-
erating instructions may be carried out. Any other
maintenance work must be carried out by our Cus-
tomer Service.
• Do not modify the power saw in any way as this
could jeopardize its safety.
• Should the chainsaw fail despite our careful manu-
facturing and inspection procedures, have it re-
paired by an authorized Customer Service work-
shop.
Filling in chain oil
To prevent dirt getting inside the tank, clean the oil
tank cap (21) before opening. Check the contents of
the oil tank during sawing work by checking the oil
gauge (15). Close the oil tank cap tightly and wipe
away any spills.
Sharpening the saw chain
You can have your saw chain sharpened fast and cor-
rectly by specialist dealers, from whom you can also
obtain chain sharpening equipment to enable you to
sharpen the chain yourself.
Please follow the corresponding operating instruc-
tions.
Take care of your tools. Keep your tools sharp and
clean to enable you to work well and safely.
Follow the maintenance regulations and the instruc-
tions for changing tools

11. Storage

• Before every transport and storage, attach the
chain guard.
• Store the device in a dry place beyond the reach
of children.
• When the device is not being used, store it so it
cannot be started by unauthorised persons.
34 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Warning!
Do not store the device without protection outside or
in a damp environment.

12. Electrical Connection

The installed electric motor is connected and is
ready to work. The connection complies with the
relevant VDE and DIN regulations. If it is necessary
to replace the connection cable, this must be done
by the manufacturer or their representative to avoid
safety hazards. The customer-side mains supply and
the used extension line must meet these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Defective Electric Connection Lines
Often, insulation damages occur on electrical con-
nection lines.
Causes are:
• Drag marks if connection lines are led through win-
dow or door clearances.
• Kinks due to improper attachment or routing of the
connection line.
• Cuts caused by running over the connection line.
• Insulation damages caused by pulling the connec-
tion line out of the wall socket.
• Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be
used and are hazardous due to the insulation dam-
ages.
Regularly check the electrical connection lines for
damages. Please make sure that the connection
lines are disconnected from the mains supply during
the check.
Electrical connection lines must comply with the rel-
evant VDE and DIN regulations. Only use connection
lines labelled with H05VV-F. The labelling of the con-
nection cable with the type specification is required.
AC motor
• The mains voltage must be 230-240 V~.
• Extension leads up to 25 m in length must have a
cross-section of 1.5 mm
. Extension leads whose
2
length is over 25 m must have a cross-section of
at least 2.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate

Quicklinks ausblenden: