10-577
2.5. Connecting the floor push button
• Connect the floor push button to the E and P terminals.
note: If you use the Niko bell button 05-540, you need to remove the lamp.
2.6. Error detection and error message
Errors are visually and acoustically signalled: error signal sounds and both LEDS keep flashing.
Cause of errors
a and P wires switched or short circuited
a or M wire: not connected or no power supply
The button is stuck
(pressed longer than 15 s)
2.7. Settings
Pre-set times
Call duration
Timeout call suppression
Time the green LEDs flash when speech channel is in use after the speech
connection has been established
Internal standby time when device calls or is called
44
Error indication
Error sound
1
all LEDs flash
max. 2 min.
4 min.
6 s
approx. 30 s
12V 1A max
Solution
Switch a and P wires around or solve the short
2
circuit, the device will go back to standby mode
6 S
Connect a wire or check the power supply,
the device will go back to standby mode
Loosen the button in question or the floor push
button, or remove the lamp when you use the Niko
bell button 05-540
the device will go back to standby mode
flashes 3 times