Building Under
CAUTION! Only a qualified and
competent person must do the
installation of the appliance. If
you do not contact a qualified
or competent person, the
guarantee becomes invalid if
there is damage.
Before you install the appliance, fit it with
the applicable hob from the table.
Type
LES6001F
LES6061F
LEM6001E
Electrical connection with the
hob
The hob connection socket is at the top of
the oven cabinet. The hob has connection
leads for the cooking zones and the
ground cable. The leads have plug-in
connectors. To connect the hob to the
oven, plug the connectors into the correct
oven sockets. The design of the plugs and
sockets prevents incorrect connections.
Building In
min. 550
20
600
min. 560
9
3
Maximum power
6000 W
7600 W
7000 W
540
21
558
114
19
589
570
598
594
Securing the appliance to the
cabinet

Electrical installation

The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied without a main
plug and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
1
2
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
Leonard 19
A
B
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
3
4
5