Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation; Technical Information; Technical Data - Leonard LBN1310X Benutzerinformation

Vorschau ausblenden Andere Handbücher für LBN1310X:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

18 Leonard
min. 550
20
590
min. 560
9
3
Securing the appliance to the
cabinet

Electrical installation

The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.

TECHNICAL INFORMATION

Technical data

Voltage
Frequency
540
21
558
114
19
589
570
598
594
A
B
This appliance is supplied with a main plug
and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also
refer to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
230 V
50 Hz
Section of the ca-
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5

Werbung