SYSTEM SET UP
Ca p a c i t y C u t - Of f
ON
5
0 0 0 mAH
DEC. INC.
DEC. INC.
Ke y B e ep
ON
Bu z z er
ON
DEC. INC.
I n p u t P o we r L o w
Cu t - Of f
1
1 . 0 V
DEC. INC.
Ex t . T e mp
0
I n t . T e mp 3
by 11.9, set this number as the value for
safety time setting. If the charger stopped at
this threshold, about 140% of the capacity will
have been fed into the battery.
For example:
Capacity
2000mAh
3300mAh
1000mAh
This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the deltapack voltage is not
detected nor the safety time expired by any
reason, this feature will automatically stop the
process at the selected capacity value.
The beep sounds at every time pressing the
buttons to confirm your action. The beep or
melody sounded at various times during
operation to alert different mode changes.
These audible sounds can be on or off.
This program monitors the voltage of input
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.
This screen shows the external and internal
C
7 C
temperature.
Current
2.0A
(2000/2.0=1000)/11.9=84 minutes
3.0A
(3300/3.0=1100)/11.9=92 minutes
1.2A
(1000/1.2=833)/11.9=70 minutes
26
Safety Time