n Single outdoor unit
Heat Pump
Nominal
Model
Voltage
MMY-
(V-Ph-Hz)
MAP0501HT7
380-3-60
380-3-60
MAP0601HT7
MAP0801HT7
380-3-60
380-3-60
MAP1001HT7
MAP1201HT7
380-3-60
n Combination of outdoor unit
Heat Pump
Nominal
Model
Voltage
MMY-
(V-Ph-Hz)
AP1401HT7
380-3-60
380-3-60
AP1601HT7
AP1801HT7
380-3-60
AP2001HT7
380-3-60
AP2201HT7
380-3-60
AP2211HT7
380-3-60
AP2401HT7
380-3-60
AP2411HT7
380-3-60
AP2601HT7
380-3-60
AP2801HT7
380-3-60
AP3001HT7
380-3-60
AP3201HT7
380-3-60
380-3-60
AP3211HT7
AP3401HT7
380-3-60
AP3411HT7
380-3-60
380-3-60
AP3601HT7
AP3611HT7
380-3-60
AP3801HT7
380-3-60
AP4001HT7
380-3-60
AP4201HT7
380-3-60
AP4401HT7
380-3-60
AP4601HT7
380-3-60
AP4801HT7
380-3-60
Legend
MCA
: Minimum Circuit Amps
MOCP
: Maximum Overcurrent Protection (Amps)
ICF
: Maximum Instantaneous Current Flow Start
RLA
: Rated Load Amps
Downloaded from
www.Manualslib.com
Voltage
Range
Min
Max
RLA
LRA
342
418
4.2 + 4.2
342
418
4.8 + 4.8
342
418
5.4 + 5.4
342
418
6.9 + 6.9
342
418 10.0 + 10.0
Voltage
Range
Unit No.1
Unit No.2
Min
Max
RLA
LRA
RLA
342
418
5.4 + 5.4
—
4.8 + 4.8
342
418
5.4 + 5.2
—
5.4 + 5.4
342
418
6.9 + 6.9
—
5.4 + 5.4
342
418
6.9 + 6.9
—
6.9 + 6.9
342
418
5.4 + 5.4
—
5.4 + 5.4
342
418 10.0 + 10.0
—
6.9 + 6.9
342
418
5.4 + 5.4
—
5.4 + 5.4
342
418 10.0 + 10.0
—
10.0 + 10.0
342
418
6.9 + 6.9
—
5.4 + 5.4
342
418
6.9 + 6.9
—
6.9 + 6.9
342
418
6.9 + 6.9
—
6.9 + 6.9
342
418
5.4 + 5.4
—
5.4 + 5.4
342
418 10.0 + 10.0
—
6.9 + 6.9
342
418
6.9 + 6.9
—
5.4 + 5.4
342
418 10.0 + 10.0
—
10.0 + 10.0
342
418
6.9 + 6.9
—
6.9 + 6.9
342
418 10.0 + 10.0
—
10.0 + 10.0
342
418
6.9 + 6.9
—
6.9 + 9.9
342
418
6.9 + 6.9
—
6.9 + 6.9
342
418 10.0 + 10.0
—
6.9 + 6.9
342
418 10.0 + 10.0
—
10.0 + 10.0
342
418 10.0 + 10.0
—
10.0 + 10.0
342
418 10.0 + 10.0
—
10.0 + 10.0
manuals search engine
Compressor
Compressor
Unit No.3
Unit No.4
LRA
RLA
LRA
RLA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
4.8 + 4.8
—
—
—
—
—
—
—
5.4 + 5.4
—
—
—
—
—
—
—
5.4 + 5.4
—
—
—
5.4 + 5.4
—
—
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
10.0 + 10.0
—
—
—
6.9 + 6.9
—
5.4 + 5.4
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
10.0 + 10.0
—
6.9 + 6.9
—
10.0 + 10.0
—
10.0 + 10.0
LRA
: Locked Rotor Amps
FLA
: Full Load Amps
kW
: Fan Motor Rated Output (kW)
Fan Motor
kW
FLA
MCA MOCP
0.60
0.8
0.60
0.8
0.60
1.0
0.60
1.1
0.60
1.1
Fan Motor
LRA
kW
FLA
MCA MOCP
—
0.6 × 2
1.0 + 0.8
—
0.6 × 2
1.0 + 1.0
—
0.6 × 2
1.0 + 1.1
—
0.6 × 2
1.1 + 1.1
—
0.6 × 3
1.0 + 1.0 + 0.8
—
0.6 × 2
1.1 + 1.1
—
0.6 × 3
1.0 + 1.0 + 1.0
—
0.6 × 2
1.1 + 1.1
—
0.6 × 3
1.1 + 1.1 + 1.0
—
0.6 × 3
1.1 + 1.1 + 1.0
—
0.6 × 3
1.1 + 1.1 + 1.1
—
0.6 × 4
1.0 + 1.0 + 1.0 + 1.0
—
0.6 × 3
1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.0 + 1.0 + 1.0
—
0.6 × 3
1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.0 + 1.0
—
0.6 × 3
1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.0
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
—
0.6 × 4
1.1 + 1.1 + 1.1 + 1.1
NOTE :
RLA is based on the following conditions.
Indoor temperature
Outdoor temperature : 35°C DB
60Hz
Power Supply
ICF
16.5
20
—
16.5
20
—
20.0
30
—
22.5
30
—
24.5
30
—
Power Supply
ICF
36.5
40
—
40.0
50
—
42.5
50
—
45.0
60
—
56.5
70
—
47.0
60
—
60.0
70
—
49.0
60
—
62.5
70
—
65.0
80
—
67.5
80
—
80.0
90
—
69.5
80
—
82.5
100
—
71.5
80
—
85.0
100
—
73.5
90
—
87.5
100
—
90.0
100
—
92.0
110
—
94.0
110
—
96.0
110
—
98.0
110
—
: 27°C DB/19°C WB